8.18  SMOKE RPM VARIATION (SEE SECTION I  SETTINGS MENU A PAG. 14)

Changes to be made with the support of the authorised technician.

Activates only with the Easy Set function disabled,

 "SET: 0" 

!

If the installation presents difficulties for smoke evacuation (no draught or no pressure in the duct), the smoke and ash expulsion 

speed can be increased. This change resolves all the potential problems related to pellets clogging in the brazier and deposits 

forming at the bottom of the brazier itself caused by poor quality fuel or fuel that produces a lot of ashes. The values available are 

from -27% to +27% with variations of 3 points at a time. The variation in negative can be used in case the flame is too low.

8.19  CHIMNEY SWEEP FUNCTION (FOR MAINTENANCE TECHNICIANS ONLY) - SEE SECTION K SET-

TINGS MENU A PAG. 14

This function can be activated only when the boiler is on and with power output and heating operation power with parameters 

P5, with fan (if present) in V5. Any loading/smoke ventilation percentage corrections must be taken into account. This status lasts 

20 minutes, the countdown is displayed on the panel. At any time the technician can interrupt this stage by quickly pressing the 

on/off key.

FUEL

9.1 

FUEL

•  Use top-quality pellets because they have influence in the calorific value and in ash remains.

•  Not adequate pellets cause a bad combustion, a frequent burning pot obstruction and exhaust conduits obstruction. Further it 

decreases the calorific value, soils the glass and increases consumptions and ash and unburnt granules quantity.

Humid pellets cause a bad combustion and running, so please assure you that they are stored in dry places and 

far at least one meter from the stove and/or any other source of heat.

•  It is advisable to try different type of pellets available on the market and to choose that which gives the best performance.

•  Pellets of variable quality and size are available on the market: the smaller the pellet, the greater the fuel supply, resulting in 

poor combustion

Depending on the type of pellets it could be necessary a parameters adjustment, please contact an Authorized 

Assistance Service.

The main quality certifications for pellets currently available on the European market guarantee that the fuel complies with class 

A1/A2 according to ISO 17225-2. These certifications include, for example, ENPlus, DINplus, Ö-Norm M7135, and specifically assure 

that the following characteristics are complied with:

•  calorific value: 4.6 - 5.3 kWh/kg.

•  Water content: ≤ 10% of the weight.

•  Percentage of ash: max 1.2% of the weight (A1 less than 0.7%).

•  Diameter: 6±1/8±1 mm.

•  Length: 3-40 mm.

•  Content: 100% untreated wood without the addition of binding agents.

The company recommends using certified fuel for its products (ENPlus A1, DINplus, Ö-Norm 

M7135).

The use of pellets that do not comply with the characteristics specified previously may com-

promise the operation of your product and therefore invalidate the warranty and product 

liability.

Summary of Contents for PRINCE 11

Page 1: ...EN USER MANUAL Pellet Stove PRINCE 11 KOBE 11 FENICE 11 PRINCE PLUS 11 KOBE PLUS 11 FENICE PLUS 11 SPARK 11 INDACO 11 OriginalInstructions 2022CADELsrl Allrightsreserved Tuttiidirittiriservati new...

Page 2: ...16 EASYSETFEATURE SEESECTIONXSETTINGSMENU A PAG 14 20 8 17 PELLETS RECIPE SEE SECTION H SETTINGS MENU A PAG 14 21 8 18 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 14 22 8 19 CHIMNEY SWEEP FU...

Page 3: ...lost you can request another copy from the localTechnical Dept or download it directly from the company s website Alllocalregulations includingthosereferringtonationalandEuropeanstandards mustbeobserv...

Page 4: ...the interval between routine maintenance operations according to the operating condition of the product We furthermore point out that these operating conditions increase the risk of premature wear of...

Page 5: ...meter If the floor is made of combustible material we recommend using a protector made of in combustiblematerial steel glass etc thatalsoprotectsthefrontpartfromanyfallingburnt particles during cleani...

Page 6: ...ntheproductisswitchedonforthefirsttime itisnormalforittoemitsmokeduetothepaintheatingupforthefirsttime Therefore make sure the room it is installed in is well ventilated Periodically check and empty t...

Page 7: ...ault the customer must have the guarantee certificate and present it with the proof of purchase document to theTechnical Assistance Office Theguaranteedoesnotcovermalfunctionsand ordamagetotheapplianc...

Page 8: ...rvices 6 DISPOSAL OF MATERIALS 6 1 WARNINGS FOR THE CORRECT DISPOSAL OF THE PRODUCT The owner is the sole party responsible for demolishing and disposing of the product This must be performed in compl...

Page 9: ...TORS Fig 2 Wastedisposal Thissymbol whichisusedontheproduct batteries accumulatorsoronthepackagingordocuments meansthatattheendofits useful life this product the batteries and the accumulators include...

Page 10: ...he com petent body APPLIANCE BAG BAG OF ACCESSORIES BUBBLEWRAP PROTECTIVE SHEET LABELS POLYETHYLENE LD PE 04 SORTED waste collection PLASTIC Check the instructions of the com petent body POLYSTYRENE F...

Page 11: ...US ProcedureifonlyvalidformodelswithEASYCONNECTPLUSWi Fitechnology Fig 3 EASYCONNECTPLUSmodule Fig 4 EASYCONNECTPLUSdisplay Fig 5 EASYCONNECTPLUSapp The documentation for connecting theWi Fi and using...

Page 12: ...roperty or in the event of failedoperation The Wi Fi module uses the domestic Wi Fi network ensure there is enough coverage in the place of installation N B forstoveswitha3 buttondisplay theprogrammab...

Page 13: ...tee Oily plant waste and lacquers can cause smells and smoke during the first working hours it is advisable to ventilatetheroombecausetheycouldbenoxioustopeopleandanimals Set values from 1 to 5 are de...

Page 14: ...Loading displayed only when the boiler is switched off d Tone e Ext Thermostat activation f Auto Eco activation g OffTime Eco default 5 minutes x Easy Set h Pellet Recipe i Smoke Fan rpm j ComponentsT...

Page 15: ...Scroll to Settings using the arrows Press menu to confirm Scroll to Auto Eco activation using the arrows Press menu to confirm Select On with the keys Press menu to confirm and esc to exit g OffTime...

Page 16: ...ng the arrows Press menu to confirm Scroll to the Chimney Sweep Function function using the arrows Press menu to confirm Select On with the keys Off by default Press menu to confirm and esc to exit l...

Page 17: ...blackens and the burningpottobecomeencrusted cleanthestove cleanthefumeconduitandthechimneyflue ATTENTION Makesurepelletsandashhavenotaccumulatedinthebrazierduetofailedignition Ifthebrazierisnotclea...

Page 18: ...6 Fig 14 Display Fig 15 Display Fig 16 Display Withfunction 1 or 2 or 3 or 4 or 5 thefanisforcedtoworkattheselectedoutput Forexample bysetting 3 evenifthe fan is set to heat output 5 it will work as i...

Page 19: ...or keyhighlightwiththewhitebackgroundthedayinwhichonewishestoactivatethetimerandconfirmwiththe menu key Ifno day of the week is confirmed as active in turn the timer programme will not appear active...

Page 20: ...procedure begins the panel shows Off Active Eco small flashing flame see Fig 21 When the stove is switched off the panel shows active OFF ECO with the flame icon off For an ECO switch on the following...

Page 21: ...madewiththesupportoftheauthorisedtechnician ActivatesonlywiththeEasySetfunctiondisabled SET 0 Thisfunctionisforadaptingthestovetothepelletsthatarebeingused Infact asthereareseveraltypesofpelletsonthem...

Page 22: ...causeabadcombustion afrequentburningpotobstructionandexhaustconduitsobstruction Furtherit decreases the calorific value soils the glass and increases consumptions and ash and unburnt granules quantity...

Page 23: ...pression alarm and proceeds to switch off Wait until it switches off then light it again Fig 26 Dooropen Fig 27 deterioratedgasket Fig 28 Timer 90seconds Tooperatecorrectly thestovemustworkwiththepell...

Page 24: ...mperature 0 C 50 C 38 khz infrared signal Used batteries contain metals which are harmful for the environment they must therefore be disposed of separately in the special containers Fig 30 Remotecontr...

Page 25: ...run until the flame goes out due to lack of fuel and until a minimum level of cooling is reached 12 7 TEMPORARY POWER CUT If the power cut lasts less than 10 the boiler returns to its previous operati...

Page 26: ...utine maintenance alert it does not block the system When this flashing message appears upon start up it means that the preset operating hours have elapsed before maintenance Contact the service centr...

Page 27: ...UPANDOPTI MALOPERATIONOFYOURPELLETPRODUCT For the brazier to be cleaned properly remove it from its housing completely and thoroughly clean all the holes and the grate on the bottom If good quality p...

Page 28: ...they must be removed with the aid of a vacuum cleaner see Fig 37 13 5 FUME PIPES ANNUAL CLEANING Clean annually from soot with brushes The cleaning operation must be executed by a specialized stove re...

Page 29: ...orTechnicalAssistanceCentre during thenecessaryannualendofseasonscheduledmaintenanceoperations Thiswaythepaintwillprotecttheinnerpartsofthecom bustion chamber blocking any type of oxidative process Fi...

Page 30: ...M SOLVING Before of every Authorized Technician intervention the same Technician has the duty to check if the parame tersofthemotherboardcorrespondtothoseofthetableyouown Incaseofdoubtsregardingtheuse...

Page 31: ...t loading Check if on the display there is an ACTIVE ALARM Have the stove checked Flames are weak and orange coloured pellets do not burn properly and the glass blackens Not sufficient com bustion air...

Page 32: ...elisation can be noxious to health The stove is at its highest power but does not heat up Ambient temperatu re reached The stove is at its minimum value Increase the desired ambient temperature Stove...

Page 33: ...Nm3 Heat output Nominal heat output Pnom 10 5 kW Minimum heat output indicative Pmin 3 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 90 Useful efficiency at min...

Page 34: ...0 mg Nm3 NOx al 13 O2 130 mg Nm3 Heat output Nominal heat output Pnom 10 5 kW Minimum heat output indicative Pmin 3 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom...

Page 35: ...35 KOBE FENICE SPARK INDACO PRINCE...

Page 36: ...CADEL srl 31025 S Lucia di Piave TV Via Foresto sud 7 Italy Tel 39 0438 738669 Fax 39 0438 73343 www cadelsrl com www free point it www pegasoheating com Rev 00 2022...

Reviews: