33
KOBE - FENICE - SPARK - INDACO - PRINCE
15 TECHNICAL DOCUMENTATION FOR LOCAL SPACE HEATERS ACCORDING TO
COMMISSION REGULATIONS (EU) 2015/1185 - (EU) 2015/1186 (PRODUCT FI-
CHE)
Manufacturer
CADEL srl - Via Foresto Sud 7 - 31025 Santa Lucia di Piave (TV) - Italy
Trademak: model identifier
CADEL: PRINCE 11 T1 - KOBE 11 T1 - FENICE 11 T1
Description
Pellet stove
Indirect heating functionality
No
Direct heat output
10,5 kW
Indirect heat output
- kW
CPR harmonised standard
EN 14785
Notified body
ACTECO Srl (N.B.1880)
Preferred fuel (unique)
Compressed wood with moisture content < 12 %
YES
Wood logs with moisture content ≤ 25 %
NO
Other woody biomass
NO
η
s
86
%
EEI
127
-
Energy Efficiency Class (A++ to G scale)
A+
Space heating emissions at nominal heat output
PM (al 13% O
2
)
15
mg/Nm
3
OGC (al 13% O
2
)
5
mg/Nm
3
CO (al 13% O
2
)
159
mg/Nm
3
NO
x
(al 13% O
2
)
100
mg/Nm
3
Space heating emissions at minimum heat output
Only required if correction factors F(2) or F(3) are applied
PM (al 13% O
2
)
20
mg/Nm
3
OGC (al 13% O
2
)
5
mg/Nm
3
CO (al 13% O
2
)
230
mg/Nm
3
NO
x
(al 13% O
2
)
130
mg/Nm
3
Heat output
Nominal heat output (P
nom
)
10,5
kW
Minimum heat output (indicative) (P
min
)
3
kW
Useful efficiency (NCV as received)
Useful efficiency at nominal heat output (η
th,nom
)
90
%
Useful efficiency at minimum heat output (indicative)
(η
th,min
)
90
%
Auxiliary electricity consumption
At nominal heat output (el
max
)
0,110
kW
At minimum heat output (el
min
)
0,015
kW
In standby mode (el
sb
)
0,003
kW
Type of heat output/room temperature control (select
one)
Single stage heat output, no room temperature control
NO
Two or more manual stages, no room temperature
control
NO
With mechanic thermostat room temperature control
NO
With electronic room temperature control
NO
With electronic room temperature control plus day
timer
NO
With electronic room temperature control plus week
timer
YES
Other control options (multiple selections possible)
Room temperature control, with presence detection
NO
Room temperature control, with open window detec-
tion
NO
With distance control option
NO
Permanent pilot flame power requirement
Pilot flame power requirement (if applicable) (P
pilot
)
N.A.
kW
Observe the specific precautions for installation, assembly and maintenance indicated in the manual accompanying the
product.
Issue date: 28.12.2021