32
8.3
FUME CONDUIT CLEANING
The exhaust system must be cleaned every 2/3 months.
Fig. 53 - Fume conduit cleaning
• Remove the inspection lid of the T-union (see
).
• Extract the ash which has accumulated in the inner.
• After cleaning repeat the operation in reverse order, checking the condition and efficiency of the gasket, and if necessary
replace it.
It is important to sealed the cap othrwise noxiuous fumes will propagate among the room.
8.4
SMOKE EXTRACTOR COMPARTMENT CLEANING
At the back of ash drawer “D”, you will find smoke cover “E”, which must be removed to clean the smoke extractor. Therefore:
• loosen screws “s”
• remove smoke cover “E”
At this point, use a vacuum cleaner nozzle to remove the ash and soot that have accumulated in the lower exchanger shown by the
arrow. Before reinstalling cover “E”, we recommend replacing gasket “F”
Before vacuuming the ash, we recommend cleaning the inner walls of the stove with a scraper.
Fig. 54 - Lower compartment cleaning
8.5
CLEANING THE SMOKE EXTRACTION SYSTEM AND GENERAL CHECKS
Clean the smoke exhaust system especially near the “T”-fittings, elbows, and any horizontal sections of the smoke
duct.
Contact a qualified chimney sweep to periodically clean the flue.
Check the ceramic fibre gasket seal on the stove door. If necessary, order new gaskets from the dealer for replacement or contact
an authorised service centre to perform the entire operation.
ATTENTION:
The fume exhaust system cleaning frequency depends on stove use and its installation.
We recommend contacting an authorised service centre for the end-of-season cleaning and maintenance
operations because the centre will perform an overall check of the parts, as well as the above-mentioned
operations.