14
WALL - SMALL - STYLE
EN
11
INSTALLATION
11.1
INTRODUCTION
•
The assembly position must be chosen depending on environment, outlet, chimney flue.
•
Check with local authorities if there are any restrictive regulations which regard the combustible air inlet,
room ventilation, fume exhaust system together with chimney flue and chimney pot.
•
Check if there is the combustible air inlet.
•
Check the probable presence of other stoves or appliances which could depress the room.
•
Check at switched on stove if there is the presence of CO in the room.
•
Check if the chimney has the necessary draught.
•
Check if during the fume passage all has been executed in safety (probable fume losses and distances from
flammable materials, etc.…).
•
The installation of the appliance must enable an easy access for appliance, fume exhaust pipes and chimney
flue cleaning.
•
The installation must enable en easy access to the electric connection plug (see
).
•
To install more appliances, the external air inlet must be correctly dimensioned (see
11.2
OVERALL DIMENSIONS
Fig. 12 - General dimensions: Wall/Small
LEGEND
1
Hole combustion air inlet from indoor environment d.4 cm
2
Hole combustion air inlet from outdoor environment d.4 cm
3
Exhaust fumes d.8 cm
4
Hot air outlet d.8 cm
5
96 cm
6
87,5 cm
7
15,5 cm
8
26 cm
9
80 cm
10
7,3 cm
11
17.3 cm
12
17.2 cm
13
8 cm
14
87,8 cm
15
85 cm