33
WALL - SMALL - STYLE
EN
ALARM
CAUSE
SOLUTION
INTERVENTION
AL 7 - THERMAL
SAFETY
Boiler overheating
Let the stove cooling. (If the problem persits please call
an Authorized Technician).
The ambient exchanger
fan does not work
Replace the ambient fan.
Temporary power cut
The lack of tension during the running implies the
overheating of the boiler and the intervention of the
manula reset thermostat. Let the stove cooling, reset and
start the stove up again.
Faulty manual reset
thermostat
Replace the manual reset thermostat.
Faulty mother board
Replace the mother board.
AL 8 - FAILURE
DEPRESS
Obstructed exhaust
The exhaust chimney is partially or totally obstructed. Call
en expert stove-repairer who executes a check from the
exhaust up to the chimney pot.
Fume fan out of order
The pellet can burn also thanks to the chimney flue
depression without the aid of the fan. Have the fume fan
immediately replaced. It can be noxious to health to let
the stove running without fan.
Obstructed connecting
nozzle
Clean the connecting nozzle.
Faulty pressostat
Replace the pressostat.
Faulty electronic board
Replace the mother board.
Extreme chimney lenght
Contact an expert stove repairer and check that the
exhaust chimney is in compliance with regulations: see
Advers whether
conditions
In case of strong wind there can be a negative pressure
to the chimney. Check and switch the stove on again.
The fire door is not
correctly closed
Close the fire door correctly and check if the gaskets are
broken.
Fire door microswitch
faulty or out of order
Replace the fire door microswitch.