UTENTE WALL3 PLUS_TILE3 PLUS_ MOON_LEAN3 PLUS_EN
14
Fig. 12 - Display
Note: The full stop to the right of the ambient temperature shown in the control panel display (upper right) indicates the half
degree (e.g. 23.° means 23.5°C).
Air Fan Speed 1 -
this function allows selecting the desired speed for the ambient fans from 1 to 5 or A. A means automatic,
ventilation depends on power, recommended setting (see
Air Fan Speed 2
- this function allows selecting the desired speed for the DUCTING fans from 1 to 5 or A. A means automatic,
ventilation depends on power, recommended setting (see
Fig. 13 - Display
Fig. 14 - Display
With function “1” or "2" or "3" or "4" or "5" the fan is forced to work at the selected output. (For example: by setting “3”, even if the
fan is set to heat output 5 it will work as if set to heat output “3”, etc.).
If the stove is set to maximum heat output 5 and the fans to minimum output 1, this may cause overheating
and the “THERMAL SAFETY” alarm to go off.
Comfort Mode -
this function allows activating - deactivating the fans at
power 1
.
Fire
- this function allows setting the flame power from a minimum of 1 to a maximum of 5. The power levels correspond to a
different fuel consumption value: by setting 5 you can heat the room in less time, while by setting 1 you can keep the ambient
temperature constant for a longer period. The flame set goes to the minimum value automatically when the set temperature value
is reached.
If only one notch appears, the stove has a flame power equal to 1.
If 5 notches appear, the stove has a flame power equal to 5.
If the notches flash, automatic cleaning is under way.
Fig. 15 - Display
Fig. 16 - Power levels
9.12 PROGRAMMED MODE (TIMER) - MAIN MENU
Setting the current day and time is essential for the proper operation of the timer.
There are six TIMER programmes, for each one the user can decide the start-up and shutdown time as well as the day of the week