36
VENUS PLUS - GIOIA-2
EN
PROBLEM
CAUSE
SOLUTION
INTERVENTION
Flames are weak
and orange,
pellet does not
burn properly and
the glass blackens
Insufficient
combustion air
Check the following inscription: probable obstructions
for combustion air inlet from the stove back or bottom;
obstructed holes of the burning pot grid and/or burning pot
with too ash. Have the fun blades and its screw cleaned.
Obstructed
exhaust
The exhaust chimney is partly or fully obstructed. Contact
an expert stove-repairer to check the exhaust up to the
chimney pot. Please clean it immediately.
Obstructed stove
Clean the stove inner.
Exhaust fan out of
order
Pellet can burn also thank to chimney flue depression without
exhaust fan. Have the exhaust fan replaced immediately.
It can be harmful to health to run the stove without fume
exhaust fan.
Heat exchanger
fan keeps turning
even when the
stove has cooled
Faulty fume
temperature
probe
Replace the fume probe.
Faulty mother
board
Replace the mother board.
Ash nearby the
stove
Faulty or broken
door gaskets
Replace the gaskets.
Fume pipes not
sealed
Contact an Autorized Stove-repairer who will seal the
gaskets with silicone at high temperature and/or will replace
the pipes with others in compliance with current regulations.
A not sealed fume outlet can cause damages to health.
Stove running
and display
showing “WORK,
MODULAT”
Room
temperature
reached
Stove idling. NO PROBLEM!
Stove running and
display showing
“HOT EXHAUST”
Fume outlet limit
temperature
reached
Stove idling. NO PROBLEM!
Stove running and
display showing
“SERVICE”
Routine
maintenance
alert (it does not
block the system)
When this flashing message appears upon start-up, it means
that the preset operating hours have elapsed before