9.3.8 Menu M8 - ENGINEER SETTINGS
This menu item is reserved for the stove installer. After entering the password (see
Fig. 17
) it allows you to set the various opera-
ting parameters of the stove using buttons P1 (decreases) and P2 (increases).
Fig. 14 - Display: key
9.3.9 Menu M9 - PELLET TYPE
It allows you to adjust the quality of combustion and the flame based on the fuel quality or draft of the flue (see
Fig. 18
).
Thanks to this adjustment the fuel supply in the burn pot may be modified by an amount between -18% and +18% (value from
-9 = -18% to +9 = +18%).
Fig. 15 - Display: pellet type
9.3.10 Menu MA - FLUE TYPE
The RPM of the flue gas extractor fan may be changed as a percentage to counter some draft issues or reduce extraction in case of
flues with excess draft (see
Fig. 19
).
The flue gas extractor speed adjustment can vary between -18% and +18% (value from -9 = -18% to +9 = +18%).
Fig. 16 - Display: flue type
9.3.11 Menu MB - EXIT
Selecting this item by pressing button P3 (see
Fig. 20
), exits the menu and returns to the previous state.
Fig. 17 - Display: exit