23
WALL - SMALL - STYLE
EN
POS.
REFERENCE
DESCRIPTION
4
STAND-BY MODE
It activates a function which, if the set ambient temperature has been exceeded for more
then 10 minutes, start the switching off phase up. If the ambient temperature has fall at
more than 2°C, the stove will restart automatically up, starting from
Press once P3 key and with P1 and P2 keys put in "OFF" or "ON". CAUTION: do not activate if
CHRONO function is active!
5
BUZZER MODE
(audio alarm)
Press once P3 key and with P1 and P2 keys put in "OFF" or "ON".
6
INITIAL LOAD
When the stove has its first ignition, the auger is completely empty. If it should be necessary
do a precharge by pressing P3 key, then P1 key for starting up and P4 key for stop.
7
STOVE STATE
It shows all parameters connected to the stove state: this is a menu for the Authorized
Techinician
8
TECHNICA SETTING
Only for the Authorized Technician.
9
FLAME SETTING
It enables to set the flame dipending on the draught of the chimney flue.
12.4
START UP
We remind you that the first ignition must be carried out by a specialized and authorixed technician who will
check that all is installed in compliance with current regulations and checks the efficiency.
•
If inside the combustion chamber there are booklets, manuals, etc..., remove them.
•
Check if the door is correctly closed.
•
Check if the stove is correctly inserted in the electric socket.
•
Before switching the stove on, assure you the burning pot is clean.
•
To start the stove up, keep pressed P4 key for an instant till it will be shown "START" and "PREHEAT WAIT": the
preheating of the ingnition resistance starts. After 2 minutes about, it will be shown "PELLET LOAD, WAITING FIRE",
in this phase the auger loads the pellet and the heating of the resistance continues. When the temperature is
sufficiently high (after 7-10 minutes about), the ignition is considered as happened and on the display shows
"FIRE PRESENT".
•
Completed the phase "FIRE PRESENT", the control unit enter the "WORK" phase showing the set calorific power
and ambient temperature. It is in this phase that P5 and P6 keys settle the stove power from 1 to 5. If the value
of the ambient temperature exceeds the limit set on the keyboard on the temperature setting, the calorific
power will be carried at the minimum showing "WORK, MODULAT". When the ambient temperature turns
back below the set temperatur, the stove turns back to the set power.
12.5
STOVE ADJUSTMENT
The stove is adjusted according to the chimney flue and used pellets datas, as per technical characteristics (see
). If the datas do not correspond, the authorized technician can adjust the stove.
•
If the pellet is small in size and with a greater calorific power, (for example: encrusted burning pot), the pellet
drop must be decreased from the menu "FLAME SETTING", press P3 "PELLET TYPE", press P3 again "PELLET LOAD"
and with P2 key decrease the pellet quantity from -1 (which is -2%) till -9 (which is -18%).
•
If the chimney flue has a lower draught (for example: weak flame, sooty glass) the revolutions of the geared
motor must be increased from the menu "FLAME SETTING", press P5 "CHIMNEY TYPE", press P3 "FUME-EXH
CHIMNEY" and with P1 key increase the fume fan revolutions from +1 (which is +5%) till +9 (which is +30%).
•
If the chimney flue has a greater draught (for example: because of pellets fall on the burning pot) decrease
the fume fan revolutions from -1 to -9.
Pay attention if the value is positive or negative..
12.6
FAILED IGNITION
If the pellets do not burn, the failed ignition will be indicated by the alarm "FAILED IGNITION".
•
If the room temperature is lower than 10°C, the plug is not able to bear the ignition stage. To support it please
insert some pellets in the burning pot and a piece of burning firelighter igniter material on the pellets (for
example firelighters cubes).
•
Too much pellets in the burning pot, or humid pellet, or sooty burning pot make ignition difficult and create
dense white smoke which is harmful to health and can cause explosions on the combustion chamber. It is
therefore necessary not to stand in front of the stove during ignition stage if dense white smoke is present.