Fig. 23 - Installation on the existing fireplace
LEGEND
Fig. 23
1
Ceiling to protect
2
Ceiling plaster to protect from heat
3
Ventilation upper grid minimum entrance 400 cm
2
for natural hot convective air outlet
4
Hot air deflector
5
Combustible air inlet
6
Fireplace's fire plate
7
Lower air grid with minimum entrance 400 cm
2
for natural cool convective air inlet
8
Ventilation cleft of 400 cm2 for convective cool air recycling
9
Outlet clutch Ø80 mm
10
Fume pipe Ø80 mm with minimum vertical lenght of 1 mt
11
Chimney flue > Ø120 mm
12
Fume pipe Ø100 mm
13
Wall
14
Floor
15
Ceiling with wooden beams with a minimum distance from the fume pipe = 0,5 mt
16
Fire place insert
17
Pellet loading entrance
18
Locking ring