10 TECHNICAL DATAS
10.1 FUSE REPLACEMENT
•
For fuse replacement in the electric socket which stands on the back of the stove, extract the fuses to change with the aid of a
screwdriver for opening the shutter (see
Fig. 103
).
Fig. 103 - Shutter with fuses to remove
11 FEATURES
DESCRIPTION
ZEFIRO
3
- 9 kW
ZEN AIRTIGHT - 9 kW
WIDTH
69,7 cm
69,7 cm
DEPTH
55 cm
55 cm
HEIGHT
49 cm
49 cm
WEIGHT
105 kg
105 kg
INTRODUCED THERMAL POWER (Min/Max)
2,83 - 10,46 kW
2,83 - 10,46 kW
NOMINAL THERMAL POWER (Min/Max)
2,7 - 9,26 kW
2,7 - 9,26 kW
EFFICIENCY (Min/Max)
94,2 - 88,5 %
94,2 - 88,5 %
FLUE GAS TEMPERATURE (Min/Max)
79 - 197°C
79 - 197°C
MAXIMUM FLUE GAS FLOW RATE (Min/Max)
2,6 - 5,7 g/s
2,6 - 5,7 g/s
CO EMISSIONS (13% O2) (Min/Max)
0,024 - 0,012 %
0,024 - 0,012 %
OGC EMISSIONS (13% O
2
) (Min/Max)
3,3 - 2,6 mg/Nm
3
3,3 - 2,6 mg/Nm
3
NOX EMISSIONS (13% O
2
) (Min/Max)
108 - 127 mg/Nm
3
108 - 127 mg/Nm
3
Average CO CONTENT at 13% O
2
(Min/Max)
294 - 148 mg/Nm
3
294 - 148 mg/Nm
3
Average DUST CONTENT at 13% O
2
(Min/Max)
19,2 - 18,9 mg/Nm
3
19,2 - 18,9 mg/Nm
3
FLUE NEGATIVE PRESSURE (Max)
11,9 Pa
11,9 Pa
ON SHARED FLUE
NO
NO
FLUE GAS EXHAUST DIAMETER
Ø80 mm
Ø80 mm
FUEL
Pellet Ø6-7 mm
Pellet Ø6-7 mm
PELLET HEATING CAPACITY
5 kWh/kg
5 kWh/kg
PELLET HUMIDITY
≤ 10%
≤ 10%
HEATABLE VOLUME 18/20°C Coeff. 0.045 kW (Min/Max)
62,4 - 222 m
3
62,4 - 222 m
3
HOURLY CONSUMPTION (Min/Max)
0,59 - 2,17 kg/h
0,59 - 2,17 kg/h
HOPPER CAPACITY
15 kg
15 kg
RANGE (Min/Max)
25 - 6,9 h
25 - 6,9 h
POWER SUPPLY
230 V - 50 Hz
230 V - 50 Hz
ABSORBED POWER (Max)
346 W
346 W
STARTER RESISTANCE ABSORBED POWER
300 W
300 W
MINIMUM EXTERNAL AIR VENT (final cross-section)
80 cm
2
80 cm
2
SEALED CHAMBER STOVE
YES
YES
EXTERNAL AIR VENT FOR SEALED CHAMBER
60 mm
60 mm
DISTANCE FROM COMBUSTIBLE MATERIAL (back/side/bottom)
200 / 200 / 0 mm
200 / 200 / 0 mm
DISTANCE FROM COMBUSTIBLE MATERIAL (ceiling/front)
750 / 1000 mm
750 / 1000 mm