OPERATING INSTRUCTIONS (continued)

Resetting the Manual Reset Limit Control

Warranty

Fault Codes

 

Digital Display Reads                      Problem                                                         Solution

Model

:

Vo

lts:

Wa
tts:

WA
RNING! T

AVOID ELECTRICA

SHOC
K

  Disconnect power at circuit breaker before servicing.

                     

Do not operate without 

grill
.

cadetheat.com

Va

ncouver

, W
A

Mfg Date:

Before pushing

RESET

 button see

Owner

’s

 Guid

e

for display fault

codes and othe

r

troubleshooting

information.

3108579

conform

s

to UL

 STD

2021

072xxx

73

For more effective and safer operation and to prolong the life of 

the heater, read the Owner’s Guide and follow the maintenance 

instructions. Failure to properly maintain the heater will void any 

warranty and may cause the heater to function improperly. War-

ranties are non transferable and apply to original consumer only. 

Warranty terms are set out below.

LIMITED FIVE-YEAR WARRANTY: 

Cadet will repair or replace 

any Energy Plus (CE) heater found to be defective within five 

years after the date of purchase.

These warranties do not apply:

1. Damage occurs to the product through improper installation or 

incorrect supply voltage;

2. Damage occurs to the product through improper maintenance, 

misuse, abuse, accident, or alteration;

3. The product is serviced by anyone other than Cadet;

4. If the date of manufacture of the product cannot be deter-

mined;

5. If the product is damaged during shipping through no fault of 

Cadet.

6. The use of unauthorized accessories or unauthorized compo-

nents constitutes an alteration and voids all warranties. Refer to 

Cadet website or call customer service at 855.CADET.US for list 

of authorized accessories and components. 

7. CADET’S WARRANTY IS LIMITED TO REPAIR OR RE-

PLACEMENT AS SET OUT HEREIN. CADET SHALL NOT BE 

LIABLE FOR DAMAGES SUCH AS PROPERTY DAMAGE OR 

FOR CONSEQUENTIAL DAMAGES AND/OR INCIDENTAL EX-

PENSES RESULTING FROM BREACH OF THESE WRITTEN 

WARRANTIES OR ANY EXPRESS OR IMPLIED WARRANTY.

8. IN THE EVENT CADET ELECTS TO REPLACE ANY PART 

OF YOUR CADET PRODUCT, THE REPLACEMENT PARTS 

ARE SUBJECT TO THE SAME WARRANTIES AS THE PROD-

UCT. THE INSTALLATION OF REPLACEMENT PARTS DOES 

NOT MODIFY OR EXTEND THE UNDERLYING WARRANTIES. 

REPLACEMENT OR REPAIR OF ANY CADET PRODUCT OR 

PART DOES NOT CREATE ANY NEW WARRANTIES.

9. These warranties give you specific legal rights, and you may 

also have other rights which vary from state to state. Cadet nei-

ther assumes, nor authorizes anyone to assume for it, any other 

obligation or liability in connection with its products other than as 

set out herein.

If you believe your Cadet product is defective, please contact 

Cadet Manufacturing Co. at 855.CADET.US, during the warranty 

period, for instructions on how to have the repair or replacement 

processed. Warranty claims made after the warranty period has 

expired will be denied. Products returned without authorization 

will be refused.

Parts and Service

Visit cadetheat.com/parts-service for information on where to 

obtain parts and service.

Reduce-Reuse-Recycle

This product is made primarily of recyclable materials. 

You can reduce your carbon footprint by recycling this 

product at the end of its useful life. Contact your local 

recycling support center for further recycling instruc-

tions

.

The heater is protected by a temperature-limiting control. The manual reset temperature limit control is designed to open the heater cir-

cuit and stop the electrical current flow when excessive operating temperatures are detected. The problem must be assessed (typically 

the heater is blocked or needs cleaning) and the limit must be reset to resume operation.

About the Manual Reset Temperature Limit Control

Resetting the Manual Reset Temperature Limit Control

If the manual reset limit control has opened the heater circuit due to excessive operating tempera-

tures, the heater will not work until the manual reset limit button is pressed. 

The “manual reset limit button” is the red button located on the upper left side of your heater, behind 

the grill louvers located just above the digital temperature display.

After allowing the unit to cool for at least 10 minutes and resolving the problem causing the limit to 

trip (typically the heater is blocked or needs cleaning); use a narrow object such as a ball-point pen to 

access the manual reset button through the upper-left center section of the heater grill. Press FIRMLY 

and be sure to listen and feel for a click, indicating it has been reset.

No Display

No power, internal control 

faulty

Check that power is being supplied to heater. If operating on generator power, 

confirm generator setting; if display still doesn’t turn on, control is faulty. Replace 

heater assembly.

F1

Grill is interfering with dis-

play buttons

Turn power off at main disconnect panel, realign grill. Turn power back on at main 

disconnect panel.

F4

1. Line voltage is too low

2. Loose wire connections

3. Connected to wrong 

voltage

1. Clears automatically when line voltage returns to normal.

2. Check wire connections

3. Connect heater to correct voltage (CE162T or CE168T).

F6

Line voltage is too high

Clears automatically when line voltage returns to normal.

F7

Thermal limit tripped

Inspect heater for blockage, obstruction, and/or proper clearance.

1. Push mode button to 

0

 no heat position and wait for heater to cool. Push manual 

reset limit

 

control button per Reset instructions below.

F8

Internal control fault

Disconnect power, reconnect power. If F8 code returns, control is faulty. Replace 

heater assembly.

FF

Temperature is below 0 

 

degrees F (-17.8 degrees 

C), too low to display

Clears automatically when temperature is 0 degrees F (-17.8 degrees C) or above.

Page 7

Manual 

Reset 

Limit 

Button

Summary of Contents for CE163T

Page 1: ...ed when you need it and adjusts automatically to save you money You define your comfort maintains your room temperature within one degree Our most thoughtful design features Large digital display shows your room temperature and heating mode Easy intuitive one touch controls Night Away and Max Min options for extra savings and safety Improve air circulation and add comfort in off sea son with three...

Page 2: ...or fire or damage the heater 8 WARNING Risk of Fire To prevent a possible fire do not block air intakes or exhaust in any manner 9 WARNING Fire or explosion may occur A heater has hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable vapors or liquids are used or stored 10 Use this heater only as described in this manual Any other use not recommended by t...

Page 3: ...alled in either of these locations Installation on an inside wall is recommended Your Energy Plus heater is equipped with a unique built in thermostat that both regulates the heat output and provides precise tem perature control If replacing a heater controlled by an existing wall thermostat remove wall thermostat from the heater circuit and cover the hole with a faceplate TO REMOVE AN EXISTING WA...

Page 4: ...d height is 24 inches 61 cm from the floor to the bottom of the wall can See Figure 4 CONTROLS A built in digital thermostat is included May not be used with a wall thermostat REQUIRED MINIMUM distance of inches 1 9 cm from adja cent surfaces such as walls and 4 inches 11 4 cm from the floor See Figure 4 Cadet recommends 24 inches 61 cm from floor for optimum performance Heaters must be spaced at ...

Page 5: ... in the slots in bottom lip of wall can attach assembly at top with screw provided Installation STEP 3 Turn electrical power back on at the main disconnect panel WAIT 10 15 seconds for heater to power up before pushing any buttons The CE163T and CE083T Energy Plus heaters are equipped with a smart sensor that will auto adjust to your voltage supply No need to worry about whether you have 120 or 24...

Page 6: ...ll alternate with HL on the display Using the up or down button set maximum set point To preset a minimum setpoint press mode button LL will flash set low temperature setting Wait a minimum of 15 seconds for display to return to 0 and your settings will be saved To remove the lock follow same instructions and set to maximum of 86 F 30 C or minimum of 40 F 4 4 C Press to return to HEAT mode Press m...

Page 7: ...ranty claims made after the warranty period has expired will be denied Products returned without authorization will be refused Parts and Service Visit cadetheat com parts service for information on where to obtain parts and service Reduce Reuse Recycle This product is made primarily of recyclable materials You can reduce your carbon footprint by recycling this product at the end of its useful life...

Page 8: ...ccumulated inside heater 2 Poor or loose electrical connections 1 Clean heater See MAINTAINING YOUR HEATER section for instructions 2 Turn off power at circuit breaker Inspect all supply and heater wires for loose or poor connections Secure or reconnect all loose connections Do not reset circuit breaker until all connections have been checked or repaired Element heats for a moment without the fan ...

Page 9: ... para ahor rarle dinero Usted define su comodidad mantiene la tempera tura ambiente con un margen de un grado Nuestro diseño más creativo incluye Gran pantalla digital en la que aparece la tempera tura ambiente y el modo de calentamiento Controles sencillos e intuitivos con un solo toque Las opciones de Noche Ausencia y Máx Mín aportan más ahorro y seguridad Mejora la circulación del aire brinda m...

Page 10: ...electrocución No introduzca ni permita que ingresen objetos en las aberturas de la ventilación o escape ya que ello puede causar electrocución o incendio o bien dañar el calentador 8 ADVERTENCIA Riesgo de incendio Para evitar posibles incendios no bloquee las tomas de aire ni el escape de manera alguna 9 ADVERTENCIA Podrían producirse explosiones o incendios Todo calentador contiene piezas que se ...

Page 11: ... calentador existente que estuvo instalado en alguna de estas ubicaciones Se recomienda realizar la instalación en una pared interior Su calentador Energy Plus viene equipado con un exclusivo termostato incorporado que regula la generación del calor y brinda un preciso control de temperatura Si reemplazará un calentador controlado por un termostato mural actual retire dicho termostato del circuito...

Page 12: ...para un ren dimiento óptimo Si se instalan varios calentadores deje al menos tres pies 0 9 m entre ellos Corte un orificio de 8 pulgadas 20 3 cm de ancho por 10 pul gadas 26 cm de alto al lado del puntal de la pared Inserte la cámara de pared en la abertura manteniéndola alinea da con la superficie de la pared Asegure la cámara al puntal de la pared con 2 tornillos no incluidos mediante los orific...

Page 13: ...n Cerciórese de que los cables de suministro no queden atrapados entre el motor y la cámara de pared Tras confirmar que el borde inferior del calentador está posicionado en las ranuras en el reborde inferior de la cámara de pared fije el conjunto en la parte superior mediante el tornillo suministrado La Instalación Vuelva a conectar la energía en el cortacircuito o caja de fusibles ESPERE 10 a 15 ...

Page 14: ...gramar un punto de ajuste mínimo pulse el botón de modo aparecerá LL destellando fije al ajuste de baja temperatura Espere un mínimo de 15 segundos para volver a 0 y se guardarán los ajustes Para quitar el seguro siga las mismas instrucciones y fije en el máximo de 86 F 30 C o el mínimo de 40 F 4 4 C Pulse para volver al modo de calentamiento Pulse el botón de modo La pantalla muestra la tempera t...

Page 15: ...ión sobre dónde obtener repuestos y servicio Reduzca Reutilice Recicle Este producto está hecho principalmente de materiales reciclables Puede reducir la cantidad de carbono que contribuye al medio ambi ente reciclando este producto al término de su vida útil Comuníquese con su centro local de reciclaje para obtener mayores instrucciones al respecto El calentador está protegido por un control limi...

Page 16: ... estén dañados No reestablezca el cortacircuito sino hasta que se hayan reparado todos los cortocircuitos eléctricos 3 Vuelva a colocar el cortacircuito 4 Reemplace el conjunto del calentador El ventilador del calentador funciona pero no envía aire caliente 1 El botón de modo no se ha fijado en el modo HEAT Calor 2 El elemento ha fallado 1 Pulse el botón de modo y fíjelo en el modo HEAT la pantall...