TROUBLESHOOTING CHART
CONSULT LOCAL ELECTRICAL CODES TO DETERMINE WHAT WORK MUST BE PERFORMED BY QUALIFIED ELECTRICAL SERVICE PERSONNEL
The plug does
not fit receptacle
Heater does
not operate
Elements heat, fan
does not operate
Heater fan operates,
but does not discharge
warm air
Heater does not
shut off
Heater discharges
smoke
Manual reset limit
trips repeatedly
1. Heater is 240 volt requiring a 20 amp or
30 amp 240 volt receptacle (see Fig. 1)
1. Heater is or has been blocked
2. Thermostat set too low
3. Circuit breaker not turned on
4. Loose plug connection
5. Defective manual reset limit
1. Defective fan delay relay
2. Jammed fan blade
3. Defective motor
1. Manual reset limit tripped
2. Fan switch is “ON” and thermostat
setting is below actual temperature
3. Defective heater elements
4. Wire loose from elements
5. Temperature rise on heater is 40°
1. Heat loss from area is greater than
heater capacity
2. Defective thermostat
3. Fan switch in “ON” position
4. Fan dispersing warm air after shutdown
1. Dust, dirt, and lint accumulated inside
the heater
2. Jammed fan blade
1. Overheating
2. Overheating at shutdown
3. Overheating from excessive dust or
dirt particles
4. Overheating due to elevation of location
1.
DO NOT ALTER CORD.
Install the proper 240 volt receptacle (see Figure 1)
or return the heater in its original condition
1. Remove obstruction. Push manual reset button found in front lower panel
2. Turn knob clockwise until a click sound is heard
3. Turn circuit breaker on
4. Check plug connection
5. Replace manual reset limit
1. Replace the fan delay relay
2. Remove obstruction
3. Replace fan motor
1. Allow heater to cool, then push reset
2. Increase the thermostat setting; turn fan switch to “AUTO”
3. Replace elements
4. Check and correct loose wire
5. Close doors or windows. Provide additional insulation and/or heaters
Wait for room to warm up
1. Close doors or windows. Provide additional insulation and/or heaters
2. Replace thermostat
3. Change fan switch to “AUTO” setting
4. Fan will shut off in approximately 90 seconds
1. Clean heater. Blow dirt accumulation off heater with compressed air
(air compressor recommended)
2. Remove obstruction
1. Check all clearance requirements. 12” minimum clearance required
between top of heater and ceiling. Heater is not recommended for
ceiling mount
2. Discontinue use of breaker to control heater, or replace time delay switch
3. Clean heater (See “Operation and Maintenance” section for instructions)
4. Location elevation exceeds recommended 7500 feet
Symptom
Problem
Solution
©2007 Cadet Manufacturing Co.
Printed in U.S.A. Rev. 11/07 #720086
6. CADET’S WARRANTY IS LIMITED TO REPAIR OR REPLACEMENT AS SET
OUT HEREIN. CADET SHALL NOT BE LIABLE FOR DAMAGES SUCH AS
PROPERTY DAMAGE OR FOR CONSEQUENTIAL DAMAGES AND/OR
INCIDENTAL EXPENSES RESULTING FROM BREACH OF THESE WRITTEN
WARRANTIES OR ANY EXPRESS OR IMPLIED WARRANTY.
7. IN THE EVENT CADET ELECTS TO REPLACE ANY PART OF YOUR CADET
PRODUCT, THE REPLACEMENT PARTS ARE SUBJECT TO THE SAME
WARRANTIES AS THE PRODUCT. THE INSTALLATION OF REPLACEMENT
PARTS DOES NOT MODIFY OR EXTEND THE UNDERLYING WARRANTIES.
REPLACEMENT OR REPAIR OF ANY CADET PRODUCT OR PART DOES NOT
CREATE ANY NEW WARRANTIES.
8. These warranties give you specific legal rights, and you may also have other
rights which vary from state to state. Cadet neither assumes, nor
authorizes anyone to assume for it, any other obligation or liability in
connection with its products other than as set out herein.
If you believe your Cadet product is defective, please, contact Cadet
Manufacturing Co. at 360-693-2505, during the warranty period, for
instructions on how to have the repair or replacement processed. Warranty
claims made after the warranty period has expired will be denied. Products
returned without authorization will be refused.
Parts and Service
Visit support.cadetco.com for information on where to obtain parts and service.
Maintenance
: For more effective and safer operation and to prolong the life
of the heater, read the Owner’s Guide and follow the maintenance
instructions included with each heater. Failure to properly maintain the
heater will void any warranty and may cause the heater to function
improperly. Warranties are non transferable and apply to original consumer
only. Warranty terms are set out below.
LIMITED ONE-YEAR WARRANTY
: Cadet will repair or replace any Cadet
product, including thermostats, found to be defective within one year after the
date of purchase.
Model RCP
LIMITED FIVE-YEAR WARRANTY:
Cadet will repair or replace any Cadet
240 Volt Portable Unit Heater (RCP) element or motor found to be defective
within five years after the date of purchase.
THESE WARRANTIES DO NOT APPLY:
1. Damage occurs to the product through improper installation or incorrect
supply voltage;
2. Damage occurs to the product through improper maintenance, misuse,
abuse, accident, or alteration;
3. The product is serviced by anyone other than Cadet
4. If the date of manufacture of the product cannot be determined;
5. If the product is damaged during shipping through no fault of Cadet.
All manuals and user guides at all-guides.com