Filters  installation  and  Geo-Vary  grease  extractor 
adjustment 

Before starting the exhaust hood, install filters starting 
with inserting the top of the filter first in the top slot then 
lay down the base of the filters in the bottom slot where 
grease will be collected. 
 
Geo-Vary  grease  extractor  has  a  pre-determined 
setting as well as an adjustment level.  The Geo-Vary 
identification  must  always  be  in  front.    Perform  the 
adjustment  according  to  the  label  in  each  exhaust 
hood.  Refer to Annex 3. 

 

Air flow balancing 

Exhaust hood with baffle filters CAS series  

Start the exhaust fan and validate the rotation direction 
before  starting  the  air  balancing  and  make  sure  all 
filters are installed in the exhaust hood.  Have in hand 
the  specified  air  flow  requirement  for  the  good 
functioning of the exhaust hood. 
Cadexair  recommends  the  following  method  with 
measurements read with a propeller anemometer with 
a 2.75 inch wheel (70 mm). 
Perform 5 speed readings in the filters slot according 
to  the  image  below.    Readings  must  be  performed 
perpendicularly  to  the  filters  at  an  approximate 
distance  of  2  inch  (50  mm).    Evaluate  the  average 
speed by filters adding the 5 speed values then divided 
by 5. 

 

Then, multiply the average speed value by an effective 
area factor according to the filters size (refer to table 
below). 
 

Size 

Effective Area 

H x W (in)  SQ.FT 

SQ M 

16 x 16 

1,36 

0,126 

16 x 20 

1,75 

0,163 

16 x 25 

2,24 

0,208 

20 x 16 

1,75 

0,163 

20 x 20 

2,25 

0,209 

20 x 25 

2,88 

0,268 

 
For  Imperial  calculations,  use  air  flow  speed  units  in 
feet  per  minute  and  use  the  effective  area  in  square 
foots (SQ.FT) to get an air flow in cubic foot per minute 
(CFM). 
For  Metric  calculations,  use  air  slow  speed  units  in 
meters per hour and use the effective area in square 
meters  (SQ.M)  to  get  an  air  flow  in  cubic  meter  per 
hour.  To convert a cubic meter per hour air flow into 
liters per seconds, multiply the value by 0.278. 

Exhaust  hood  with  Geo-Vary  grease  extractors 
CAM series  

Before  proceeding  to  balancing,  make  sure  that  the 
filters  are  installed  in  the  exhaust  hood  and  adjusted 
as  indicated  on  the  label  inside  the  exhaust  hood 
(Refer to Annex 3). 
Start the exhaust fan and validate the rotation direction 
before  starting  the  air  balancing.    Have  in  hand  the 
specified air flow requirement for the good functioning 
of the exhaust hood. 
Cadexair  recommends  the  following  method  with 
measurements read with a propeller anemometer with 
a 2.75 inch wheel (70 mm). 
Perform 3 speed readings in the filters slot according 
to  the  image  below.    Readings  must  be  performed 
perpendicularly  to  the  filters  top  opening  at  an 
approximate distance of 2 inch (50 mm).  Evaluate the 

Summary of Contents for CA Series

Page 1: ...User Manual CA Series Version V1 0...

Page 2: ...ds IMPORTANT ATTENTION DANGER A commercial kitchen hood must always be installed by professionals according to the local construction codes in force A commercial kitchen hood ventilation system can ha...

Page 3: ...f the kitchen exhaust hood collar 5 Exhaust hood collar joint and air supply collar joint on PE series 6 Self cleaning hood CA1M series plumbing fitting 6 Electrical wiring 6 Access on top of exhaust...

Page 4: ...exhaust system 9 Inspection and maintenance of the exhaust hood fire suppression system 9 Tips and tricks 10 Problems and solutions 11 ANNEX 1 Exhaust hood weight evaluation table 14 ANNEX 2 Assembly...

Page 5: ...e exhaust kitchen hood to the sun and to a temperature above 35 Celsius These conditions can affect the adherence of the protective film glue protecting the exhaust kitchen hood and may damage the sta...

Page 6: ...haust hood height installation Lift the kitchen exhaust hood and fix the hood with the threaded rods All of the kitchen exhaust hood mounting brackets must be held by a threaded rod Adjust the height...

Page 7: ...he installation and construction is completed Exhaust hood skirting It is possible to install a hood skirting provided by Cadexair or not above the hood The installation method may vary according to t...

Page 8: ...s adding the 5 speed values then divided by 5 Then multiply the average speed value by an effective area factor according to the filters size refer to table below Size Effective Area H x W in SQ FT SQ...

Page 9: ...be used the same way to facilitate the balancing of many exhaust hoods on the same exhaust fan The air flow will adjust according to the opening of the Geo Vary grease extractor If modifications are t...

Page 10: ...ractor Weekly maintenance Remove baffle filters and clean or soak with a hot water and degreaser solution Empty all grease cups located under modular extraction baffles Monthly maintenance Remove and...

Page 11: ...ial kitchen operates usually out of standard working hours evenings and week end It is recommended to have in inventory replacements exhaust and air supply fan motor belts Furthermore for critical com...

Page 12: ...Verify if the magnetic started is powered on the primary side if not verify the power system of the disconnect and the fuse on the distribution panel contact an electrician if needed If the magnetic s...

Page 13: ...ED Clean as fast as possible the suppression liquid Call the company in charge of you fire suppression system maintenance to put the system back in operation If the system is equipped with a rearming...

Page 14: ...50313 01 Installation and maintenance manual www cadexair com 13 1010 Boulevard Lionel Boulet 1 800 461 0668 Varennes Qu bec Canada J3X 1P7 water valves and change them if necessary then contact Cadex...

Page 15: ...1 7 6 1 85 6 5 2 7 2 15 7 5 2 3 8 2 45 8 5 2 6 9 2 75 9 5 2 9 10 3 05 Width CA S 27 12 30 14 33 15 36 16 39 18 42 19 45 20 48 22 Weight CA S PE 50 23 55 25 60 27 65 29 70 32 75 34 80 36 85 39 CA S M...

Page 16: ...dexair com 15 1010 Boulevard Lionel Boulet 1 800 461 0668 Varennes Qu bec Canada J3X 1P7 ANNEX 2 Assembly diagram of an exhaust hood with mecanical joints CA W series NOTE Verify carefully the install...

Page 17: ...t may cause performance issues Cleaning of the Geo Vary grease extractor When necessary remove the Geo Vary from the exhaust hood filter cage carefully noting the guillotine adjustment and position fo...

Page 18: ...ule According to the cooking type Frequency Systems serving solid fuel cooking operations Monthly Systems serving high volume cooking operations such as 24 hour cooking charbroiling or wok cooking Qua...

Reviews: