TR-MAN-4500-A
Operator's Manual - 4000M 4500M
Page 15 of 46
Step 5
Now engage the brake so that the drum will no longer rotate. By locking the drum
you will prevent the hose from being pulled off the drum connection. Obstacles (hills,
rocks, etc.) in the field can cause the hose to pull out if the drum is not locked.
Figure 15 - Engage Brake Prior to Transport
img-00127.png
Step 6
Begin pumping the liquid slowly. You must allow the system to purge the air within
the hose before raising the system to the desired operating pressure. Once the liquid
reaches the applicator, the driver should start moving to distribute the liquid. At this
point you can increase the pump rpm raising the operating pressure to the desired
level.
Pressurizing your Cadman Hard Hose Drag Reel must be done slowly
and cautiously to purge all the air from the system. Air must be purged
before bringing the system up to full operating pressure.