©2019 CAE 905K560252 v1.0
25
Setup
Step 2: Prime the Fluid Systems
To prime the IV fluid system:
a. Locate the IV FILL/DRAIN port under the skin flap on the left side of the
manikin. Connect the long tubing end of the IV stopcock assembly to the
IV
FILL/DRAIN
port.
Manikin FILL/DRAIN Port
b. Prime the IV tubing to the red-colored distilled water bag and close clamp.
c. Connect tubing to the distal port of the stopcock and turn the stopcock
lever so it is pointing towards the red-colored IV bag and then open the
clamp on the IV tubing.
Manikin with IV System Connected
d. Connect the empty 30 mL syringe to the remaining port on the stopcock.
e.Pull back on the syringe plunger to approximately the 20 mL mark to
create a vacuum and turn the stopcock lever towards the syringe.
FILL/
DRAIN
port
Fill bag
Luer lock with
stop cock
Syringe