easy2log© RT0005 Technical Information Manual
31
Technical Specification
Tag Type
Semipassive
Data Points
4000
Temperature operating range
-20°C to +70°C
Temperature Accuracy
±0.5°C typical
Monitoring Time Span
Up to 5 years
Time Accuracy
<0.01% error
RFID Interface
UHF EPC Class1 Gen2/ISO 18000-6C compatible
1
Frequency range
860 MHz ÷ 928 MHz
Read range
approx. 10m in air @ 2W ERP
Memory capacity
4k samples (8 Kbyte)
Available Memory
Up to 512 bits in EPC bank, up to 512 bits in User Memory bank
Monitoring Delay Option
Up to 18 hours
Battery Type
Li / MnO2 Model Renata CR 2450N
Battery Life
1 year (typical)
Alarms
Multiple user-configurable high temperature and low
temperature alarms, ETA alarm, MKT alarm, shelf life alarm
Shelf Life Prediction
Calculations based on Arrhenius kinetic model with customer
designation of time-temperature dependency
Shelf Life Monitoring
Provides Remaining Shelf Life information at check points with
RFID reader or manual interface
IP Rating
IP67
Dimensions (L,W,H)
107 x 107 x 8.7 mm
3
Enclosure material
PVC Tecnovil code: 21TV306TRS00000
(*)
Weight
31 g
(*)
PVC Tecnovil 21TV306TRS00000 note
:
this product is conforming to the “Decreto Ministeriale 21.03.73” (and further amended) and the European Directive
2002/72/CE (and further amended) concerning suitability of materials intended to come into contact with foodstuffs;
This product is conforming to the Regulation CE n. 1935/2004-, the reference element for the traceability is the batch
number;
the producer has adopted a HCPP systems and operates in compliance with the Technical Specification BRC//IOP/2004
(product rating B);
this product is formulated with raw materials in conformity with FDA;
this product is conforming to the Directive 94/62/CE art. 9 20.12.94: the content of heavy metal (lead mercury cadmium,
hexavalent chrome) is lower than 100 ppm.
Please note that, according to the above mentioned legislation, the final packaging suitability as regards the content has to been
tested by the user for migration and stability of the content in real condition of use. It is the responsibility of the final customer
to verify the technological suitability of the product to its end use.
Tab. 4.1: easy2log
©
RT0005 technical specification
Warnings:
-
Do not incinerate, the product contains lithium battery.
-
The activation electric field for the tag is 0.5 V/m in the range from 800 MHz up to 1 GHz. Prolonged exposure to
electric fields greater than this value must be avoided in order to preserve the battery life.
1
See § Air Link Protocol Characteristic pag. 34 for more information.