P R E L I M I N A R Y
Document type:
Title:
Revision date:
Revision:
User's Manual (MUT)
N1471 4 Channel Programmable HV Power Supply
24/03/2010
1
NPO:
Filename:
Number of pages:
Page:
00112/07:N1471.MUTx/01 N1471_REV1.DOC
38
35
Bit 1
→
RUP
1 : Channel Ramp UP
Bit 2
→
RDWN
1 : Channel Ramp DOWN
Bit 3
→
OVC
1 : IMON >= ISET
Bit 4
→
OVV
1 : VMON > VSET + 250 V
Bit 5
→
UNV
1 : VMON < VSET - 250 V
Bit 6
→
MAXV
1 : VOUT in MAXV protection
Bit 7
→
TRIP
1 : Ch OFF via TRIP (Imon >= Iset during TRIP)
Bit 8
→
OVP
1 : Power Max
Power Out > 9.3W for VOUT
≤
3KV
Power Out > 8.2W for VOUT > 3KV
Bit 9
→
OVT
1: TEMP > 105°C
Bit 10
→
DIS
1 : Ch disabled (REMOTE Mode and Switch on OFF position)
Bit 11
→
KILL
1 : Ch in KILL via front panel
Bit 12
→
ILK
1 : Ch in INTERLOCK via front panel
Bit 13
→
NOCAL
1 : Calibration Error
Bit 14, 15
→
N.C.
3.5.4.
MONITOR commands related to the module
The following table shows the strings to be used to handle monitor commands related to
the module.
String
Function (Units)
$BD:xx,CMD:MON,PAR:BDNAME
Read out module name ( N1471 )
$BD:xx,CMD:MON,PAR:BDNCH
Read out number of Channels present ( 4 )
$BD:xx,CMD:MON,PAR:BDFREL
Read out Firmware Release ( XX.X )
$BD:xx,CMD:MON,PAR:BDSNUM
Read out value serial number ( XXXXX )
$BD:xx,CMD:MON,PAR:BDILK
Read out INTERLOCK status ( YES/NO )
$BD:xx,CMD:MON,PAR:BDILKM
Read out INTERLOCK mode ( OPEN/CLOSED )
$BD:xx,CMD:MON,PAR:BDCTR
Read out Control Mode (LOCAL / REMOTE )
$BD:xx,CMD:MON,PAR:BDTERM
Read out LOCAL BUS Termination status ( ON/OFF )
$BD:xx,CMD:MON,PAR:BDALARM
Read out Board Alarm status value ( XXXXX )