NGPS – User’s Manual
34
2.3
Mounting
The NGPS is a rack-mount device since the unit form factor is designed to be
installed in a standard 19-inch cabinet.
The unit(s) shall be installed assuring that the main circuit
breaker on the front panel can be always easily operated by
user personnel.
This power supply is fan cooled, the air intake occurs at the
front panel and the exhaust exits from the rear panel. Upon
installation, allow cooling air to reach the front panel
ventilation inlets. Allow minimum 10 cm of unrestricted air
space at the front and the rear of the unit.
Use a support bar to provide adequate support for the power
supply.
The front panel of the NGPS is rated IK08 (5J) against
external mechanical impacts. The place of installation must
be chosen so that impacts with heavy equipment or tools are
unlikely
CAUTION
CAUTION
CAUTION
WARNING
NO