NGPS – User’s Manual
48
Home Screen
The NGPS
Home Screen
) is the first loaded page upon power-up (or
power-cycling of the module) and contains information on:
Left Side
•
the NGPS model;
•
the module IP address;
Central Side
•
output current readback value [A] with the light blue status bar;
•
the module Identification Name (ID);
•
output voltage readback value [V] with the green status bar;
Right Side
•
the status of the output – i.e. ON/OFF/Fault (OFF indication, without fault
condition, means that the power converter is Ready);
•
the status of the control – i.e. Local (LOC) /Remote (REM)/Fast Control (FCI);
•
the set regulation mode – i.e. constant-current (C.C.) or constant-voltage (C.V.).
Figure 21: Home Screen
If the module has experienced one or more faults – e.g. interlock intervention,
over-temperature, etc. – the home page screen would display the faults, turning also the
module OFF.
The power supply latches on every fault that is recognized by the internal logic,
so that every type of fault is recorded: this means that the first happening fault does not
ban the other ones to be recorded, permitting a better investigation of the fault cause.