Design Information
PRODUCT DIMENSIONS AND CLEARANCES
36” Range Models
16”
0D[
36” Min.
12” Minimum
to Adjacent Wall
Non-
Combustible
Material **
48” Minimum
to Combustibles
18”
Min.
3” Min.
3” Min.
Island
Cutout
Top View
´0LQ
WARNING
Installations without a
hood require 48” minimum to combustibles.
$FXVWRPKRRGLQVWDOODWLRQZLWKH[SRVHG
horizontal combustible surfaces must have
an Auto-On feature. Refer to hood installation
instructions for specific hood clearances.
The surface of the entire back wall above
the range and below the hood must be
covered with a non-combustible material
VXFKDVPHWDOFHUDPLFWLOHEULFNPDUEOHRU
other stone.
CAUTION
To prevent drafts from
DIIHFWLQJEXUQHURSHUDWLRQVHDODOORSHQLQJV
in floor under appliance and behind
appliance wall.
** As defined in the National Fuel Gas Code (ANSI
=&6$%&XUUHQW(GLWLRQ&OHDUDQFHV
from non-combustible materials are not part of the
$16,=&6$VFRSHDQGDUHQRWFHUWLILHGE\
CSA. Clearances less than 12” must be approved by
ORFDOFRGHVDQGRUWKHDXWKRULW\KDYLQJMXULVGLFWLRQ
ADDITIONAL CLEARANCES:
Allow 12” minimum clearance to an adjacent wall on
each side.
Working areas adjacent to the rangetop should have
18” minimum clearance between countertop and the
bottom of the wall cabinet.
)RULVODQGLQVWDOODWLRQPDLQWDLQLQPLQLPXPIURP
cutout to back edge of countertop and 3 in. minimum
from cutout to side edges of countertop (see top view).
12”
Minimum
Each Side
Back
Universal Utility Locations
´
Width
1”
Countertop
to Cooking
Surface
´WR´
Height to trim.
Trim to be flush
or higher than
countertop.
´'HSWKWR
Front of Bullnose
´'HSWKWR
Front of Door
7RHNLFN
leg Height
´
WR´
36”
´
´
2”
´
*DV
Electric
Electric
´
2”
36”
Minimum