49-2000061
13
Screws, wall
fasteners, washers
Duct Transition
with Damper
761Dia65
Filter
Support
INST
ALLA
TION PREP
ARA
TION
PARTS PROVIDED
Locate the hardware accessory box packed with the hood and check contents.
DUCT COVER REQUIREMENTS
We recommend that the vent hood and decorative
duct cover (if used) be on site before final framing
and wall finishing. This will help to accurately locate
studs, ductwork, and electrical service. Read these
instructions to determine if the duct cover accessory
can be used for your installation situation.
Duct Cover Accessory:
• Use the decorative duct
cover to conceal ductwork
running from the top of the
hood to the ceiling.
• The duct cover accessory
consists of 2 pieces. The
outside piece is 12” high,
the inside piece is 22”.
Nested together they are
24” minimum expanding to a
total maximum height of 34”.
• The outside piece can be
used alone to fill a 12” height.
• For heights over 12”, the ceiling bracket must be
installed to secure the cover at the top.
To avoid unsightly gaps, plan the hood installation
height for duct cover use.
• The cover will fit a 12” minimum height from the top of
the hood to the ceiling or 24” minimum and expanding
up to 34” from the top of the hood to the ceiling.
THE DUCT COVER CANNOT BE USED WHEN THE
DISTANCE ABOVE THE TOP OF THE HOOD IS
BETWEEN 12” AND 24”.
Review the following examples to ensure a trouble free
installation using the duct cover accessory.
8ft. Ceilings:
The hood
must be installed at
30” above the cooking
surface (or 66” above
the floor). the duct cover
will not fit if the hood
is installed at a lower
or higher height. Use
the outside 12” section,
discard the inside section.
9 ft Ceiling:
Install the hood 24” min. and up to a
maximum of 30” above the cooking surface. The duct
cover will expand to reach ceiling height.
10 ft. Ceiling:
Install the hood 32” min to 36” max.
above the cooking surface. The duct cover will expand
to a maximum of 34” above the top of the hood to
meet the ceiling.
Installation Preparation
2 Aluminum
Grease Filters
22”
11”
12”
12”
12”
24”
9 ft. Ceiling
30”
24”
30”
30”
10 ft. Ceiling
36” Max
32”
34”
12”
8 ft. Ceiling
30”
Summary of Contents for CVW9301