background image

CONNECTOR HOOKUP

Pressure 

regulator

Gas Flow into Range

Gas Flow into Range

Flex 

connector 

(6 ft. max.)

Adapter

Installer: Inform the consumer of the location of the gas shut-off valve.

1/2” or 3/4”  

Gas pipe

Adapter

Gas  

shut-off  

valve

Pressure  

regulator

Elbow

Elbow

Nipple

Union

Nipple

Gas  

shut-off  

valve

1/2” or 3/4” 

Gas pipe

Flexible

Option

Rigid Pipe

Option

1

  GAS SUPPLY

WARNING

 

Fire Hazard: Do not use 

a flame to check for gas leaks.

WARNING

 

Explosion Hazard: Do 

not exceed 25 ft-lbs of torque when making 

gas line connections. Overtightening may 

crack the pressure regulator resulting in fire 

or explosion hazard.

Gas Pressure Regulator

You must use the gas pressure regulator supplied 

with this range. For proper operations the inlet 

pressure to the regulator should be as follows:

   Natural  Gas:

  Minimum pressure: 6” of Water Column

  Maximum pressure: 13” of Water Column

   Propane  Gas:

  Minimum pressure: 11” of Water Column

  Maximum pressure: 13” of Water Column

If you are not sure about the inlet pressure 

contact local gas supplier.

Shut off the main gas supply valve before 

disconnecting the old range and leave it off 

until the new hook-up has been completed. 

Don’t forget to relight the pilot on other gas 

appliances when you turn the gas back on.

Because hard piping restricts movement of 

the range, the use of a CSA International-

certified flexible metal appliance connector is 

recommended unless local codes require a 

hard-piped connection. 

If the hard piping method is used, you must 

carefully align the pipe; the range cannot be 

moved after the connection is made.

To prevent gas leaks, put pipe joint compound 

on, or wrap pipe thread tape with Teflon* 

around, all male (external) pipe threads. 

A.  Install a manual shut-off valve in the gas line 

in an easily accessed location outside of the 

range. Make sure everyone operating the 

range knows where and how to shut off the 

gas supply to the range.

B.  Install male 1/2” flare union adapter to the 

1/2” NPT internal thread at inlet of regulator. 

Use a backup wrench on the regulator fitting 

to avoid damage.

C.  Install male 1/2” or 3/4” flare union adapter 

to the NPT internal thread of the manual 

shut-off valve, taking care to back-up the 

shut-off valve to keep it from turning.

D.  Connect flexible metal appliance connector 

to the adapter on the range. Position range 

to permit connection at the shut-off valve.

E.  When all connections have been made, make 

sure all range controls are in the off position 

and turn on the main gas supply valve. 

Use a liquid leak detector at all joints and 

connections to check for leaks in the system.

When using pressures greater than 1/2 psig 

to pressure test the gas supply system of the 

residence, disconnect the range and individual 

shut-off valve from the gas supply piping. When 

using pressures of 1/2 psig or less to pressure 

test the gas supply system, simply isolate the 

range from the gas supply system by closing 

the individual shut-off valve.

When checking for proper operation of the 

regulator, the inlet pressure must be at least 1” 

greater than the operating (manifold) pressure 

as given on rating label of product. 

*Teflon: Registered trademark of DuPont

2

  ELECTRICAL 

CONNECTIONS

WARNING

 

Shock Hazard: This 

appliance must be properly grounded. 

Failure to do so can result in electric shock.
Electrical Requirements - 

120-volt, 60 Hertz, 

properly grounded dedicated circuit protected 

by a 15-amp or 20-amp circuit breaker or time 

delay fuse.

Note: 

Use of automatic, wireless, or wired 

external switches that shut off power to the 

appliance are not recommended for this product.

Grounding

The power cord of this appliance is equipped 

with a three-prong (grounding) plug which plugs 

into a standard three-prong grounding wall 

receptacle to minimize the possibility of electric 

shock hazard from this appliance.
The customer should have the wall receptacle 

and circuit checked by a qualified electrician to 

make sure the receptacle is properly grounded.

Where a standard two-prong wall receptacle is 

encountered, it is the personal responsibility and 

obligation of the customer to have it replaced with 

a properly grounded three-prong wall receptacle.

DO NOT, UNDER ANY CIRCUMSTANCES, 

CUT OR REMOVE THE THIRD (GROUND) 

PRONG FROM THE POWER CORD. DO 

NOT USE AN ADAPTER. DO NOT USE AN 

EXTENSION CORD.

Ground Fault Circuit Interrupters (GFCI’s) are 

not required or recommended for gas range 

receptacles. Performance of the range will not be 

affected if operated on a GFCI-protected circuit 

but occasional nuisance tripping of the GFCI 

breaker is possible.

Ensure proper 

ground exists 

before use

3

  SURFACE BURNERS

WARNING

 

Fire or Explosion Hazard: 

Do not operate the burner without all burner 

parts in place.

A.  

Burners -

 Place surface burners into 

corresponding positions on cooktop.

B.  

Caps -

 Place caps on proper size burner.

C.  

Grates -

 The left and right grates are 

interchangeable. Place the grates on the 

cooktop.

Left

Grate

Right

Grate

Center 

Grate or Griddle

Electrode

Cap

Burner

Summary of Contents for JGB660

Page 1: ...tch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a pro...

Page 2: ...CATIONS CONVERTING TO PROPANE GAS OR CONVERTING BACK TO NATURAL GAS FROM PROPANE This range leaves the factory set for use with natural gas If you want to convert to propane gas the conversion must be...

Page 3: ...ns have been made make sure all range controls are in the off position and turn on the main gas supply valve Use a liquid leak detector at all joints and connections to check for leaks in the system W...

Page 4: ...NG Never completely remove the leveling leg as the range will not be secured to the anti tip device properly Follow instructions supplied with ANTI TIP bracket Anti Tip Bracket Kit Included INSTALLATI...

Page 5: ...r nsito Cualquier m todo para asegurar la cocina es adecuado siempre y cuando se realice conforme con los est ndares que figuran a continuaci n ADVERTENCIA RIESGO DE INCENDIO O EXPLOSI N Si la informa...

Page 6: ...derecho 6 Lado izquierdo Altura m nima hasta la pared lateral 36 30 2 5 4 9 13 14 1 2 24 4 1 2 12 1 2 Pared Lateral Suministro de gas y electricidad CONVERTIR A GAS PROPANO O VOLVER A CONVERTIR DE PRO...

Page 7: ...das las conexiones se hayan realizado aseg rese de que todos los controles de la cocina est n en la posici n de apagado y encienda la v lvula de suministro principal de gas Use un detector de p rdida...

Page 8: ...la unidad y ajuste la altura de la pata trasera de modo que quede correctamente adherida Nivel de Agua NOTA La placa de cocci n debe estar a la misma altura o m s arriba que la mesada Mesada 0 o Super...

Reviews: