15. SPARE PARTS 

To   order   spare   parts   indicate:   

a)   Serial   number   of   the   pump   and   of   the   engine.   

b)   Serial   number   and   name   of   the   wanted   spare   part.   

 

15.1   REPLACING   THE   SPARE   PARTS   

Diaphragm:   Use   a   19   mm   wrench.   Loosen   the   bolts   connecting   pump   body   to   reducer   support;   loosen   the   bolts   

fixing   the   connecting   rod   to   the   diaphragm   locking   adapter.   To   assemble   proceed   in   reverse   order.   

                              Attention:   support   the   engine-­‐reducer   during   this   operation   using   appropriate   lifting   means   ensuring   the   

pump   lifting   hook   is   suitable   for   the   correct   balancing   of   the   load;   therefore   use   appropriate   means.   

Suction   and   delivery   valves:   

                              Use   a   19   mm   wrench;   loosen   the   two   fastening   bolts   and   replace.   A   valve   fixing   pin   is   positioned   on   the   

pump   body   that   facilitates   correct   installation.   

Spring   connecting   rod:   

In   case   of   repairing   the   connecting   rod   item      218L540I,   ensure   the   total   length   of   the   same   is   305   mm.   

   

   

   

Other   spare   parts:   

                              To   replace   other   parts,   refer   to   the   spare   parts   catalogue   with   exploded   view   of   the   parts;   it   is   advisable   to   

contact   your   usual   supplier   for   particular   repairs.   

All    repair    operations    regarding    the    engine    must    be    carried    out    in    compliance    with    the    instructions    and   

maintenance   manual   of   the   engine,   attached   to   this   manual.   

 

FASTENING TORQUES 

Between 

and 

Model 

Fastening torque 

Notes 

[

kgm

]

 

[

Nm

]

 

BODY      

PORT   

LIB-­‐1/3”   

2,5   

24,5   

Tightens   the   valve   

SUPPORT   

BODY   

LIB-­‐1/3”   

4   

39,2   

Tightens   the   diaphragm   

CONNECTING   ROD    PLATE      

LIB-­‐1/3”   

3,5   

34,3   

   

REDUCER      

SUPPORT   

LIB-­‐1/3”   

3,5   

34,3   

   

COVER   

BODY   

LIB-­‐1/3”   

1,6   

15,7   

Tightens   cover   and   reducer   

carter   

 
 

16. DISPOSAL 

In    case    of    demolishing    the    machine    or    placing    it    out    of    service,    differentiate    the    parts    according    to    the   

manufacturing    materials    and    dispose    of    them    complying    with    the    current    Standards    in    the    country    where   

demolition   or   placing   out   of   service   takes   place.   

 

 

 

 

Summary of Contents for Libellula 1/3" aluminium on frame

Page 1: ...EN USE AND MAINTENANCE INSTRUCTIONS SELF PRIMING DIAPHRAGM PUMPS LIBELLULA 1 3 SERIES Read this user manual before installing operating using and maintaining this equipment www caffinipumps it GB...

Page 2: ...OPERATE THE PUMP UNTIL YOU HAVE READ AND UNDERSTOOD THIS MANUAL CAFFINI PUMPS DECLINES ALL AND EVERY LIABILITY FOR DAMAGE DUE TO NEGLIGENCE AND FAILURE TO COMPLY WITH THE INSTRUCTIONS IN THIS MANUAL...

Page 3: ...NG AND TRANSPORT 9 11 STORAGE 9 12 INSTALLATION 10 13 BEFORE START UP 11 14 MAINTENANCE 12 15 SPARE PARTS 13 16 DISPOSAL 13 17 OPERATING PROBLEMS CAUSES AND SOLUTIONS 14 18 FEATURES 15 1 PRESENTATION...

Page 4: ...ed on appropriate plate or punched near the oil introduction plug and the serial and or series number All our products have a 12 month warranty starting from the commissioning date and however for not...

Page 5: ...rs of work The reducer connecting the engine to the connecting rod handle system can be made of light aluminium alloy or in cast iron The transmission gears can be straight or helical teeth with drive...

Page 6: ...DED USE The pump is suitable for handling liquids or muds with solid parts in suspension The pump has dry functioning possibility at indeterminate time The Libellula 1 3 can also be suitable for the t...

Page 7: ...lative distribution of measurement in time and in frequency of the acoustic pressure level of the Libellula 1 3 pump for every required soundproofing intervention 8 SAFETY AND ACCIDENT PREVENTION IMPO...

Page 8: ...It is forbidden to stand under the loads It is forbidden to remove the ATTENTION Safety protections Do not open with the engine running INSTRUCTION FOR THE USE AND MAINTENANCE LIBELLULA 1 3 SERIES ve...

Page 9: ...riate harness Handling must be carried out by specialised staff to avoid damaging the machine and causing accidents to staff The lifting points of the various components must only be used to lift the...

Page 10: ...ted by ball or shutter valve Ensure all joints are perfectly air sealed check the threads the gaskets of the adapters of the ports and of the quick couplings Install the pump as close as possible to t...

Page 11: ...turns in one direction or the other The incorrect rotation direction causes a significant reduction of the flow rate and an incorrect functioning of the reducer The correct rotation direction is that...

Page 12: ...hrough the refuelling plug rod Every three months check the diaphragm and the valves for wear During the winter period with the machine still protect the pump from freezing drain any liquids from insi...

Page 13: ...that facilitates correct installation Spring connecting rod In case of repairing the connecting rod item 218L540I ensure the total length of the same is 305 mm Other spare parts To replace other part...

Page 14: ...suction filter 6 Remove the solid body Low flow rate 1 The rotation speed is too low 2 The delivery pipe is undersized or blocked 3 Too many curves or delivery pipe too long 4 Use of non reinforced c...

Page 15: ...x352x614 mm Net weight 36 kg 79 kg PUMP Type Self priming diaphragm with self lubricated spring or rigid connecting rod Suction ports diameter 3 BSP or DN80 PN10 Delivery ports diameter 3 BSP or DN80...

Page 16: ...CAFFINI CIPRIANO S r l 43044 LEMIGNANO DI COLLECCHIO Parma ITALY Via G Di Vittorio 46 Tel 39 0521 804325 Fax 39 0521 804145 info caffinipumps it w w w c a f f i n i p u m p s i t...

Reviews: