background image

INSTRUCTION FOR THE USE AND MAINTENANCE - LIBELLULA 1/3” SERIES - Vers. 1/16

6

INSTRUCTION FOR THE USE AND MAINTENANCE  - LIBELLULA 1/3" SERIES –vers. 01/16 

 

 

Electric motors: 

a)closed    three-­‐phase,    self-­‐ventilated    externally    insulated    in    class    F,    IP55    protection,    unified    Standards    IEC    or   

NEMA   C.   

b)   flame   proof   three-­‐phase   compliant   with   Directive   2014/34/EC   (ATEX).   

c)   externally   self-­‐ventilated   closed   single-­‐phase.   

d)   externally   self-­‐ventilated   closed   direct   current.   

 

The   pump-­‐engine   coupling   is   monobloc   with   adapter   and   appropriate   pinion.   

The   speed   variator   Stoeber   type   R37.0000   or   other   brands   with   same   features   can   be   installed   between   the   engine   and   the   

reducer.   

The    Libellula    1/3"    can    be    installed:    on    fixed    base,    on    carrying    frame,    on    trolley    for    electric    motor,    petrol    or    diesel    with   

driven   handles   or   wraparoud.   

The   machine   is   provided   with   permanent   PVC   protection   or   metal   net   with   connecting   rod-­‐handle   system   cover   to   prevent   

accidents    due    to    operator-­‐moving    parts    contact.    The    permanent    protection    is    locked    and    held    in    its    right    position    by   

fastening   bolts.   

The    machine    is    provided    with    lifting    hook    suitable    for    handling    the    pump    coupled    with    the    engine    supplied    by    the   

manufacturer   and   in   the   installation   version   (trolley   or   frame),   envisioned   during   ordering.   
               

!

   

                                             

 

 

 

6. USE  

 

6.1   INTENDED   USE   

The   pump   is   suitable   for   handling   liquids   or   muds   with   solid   parts   in   suspension.   

The   pump   has   dry   functioning   possibility   at   indeterminate   time.   

The   Libellula   1/3"   can   also   be   suitable   for   the   transfer   of   food   liquids;   in   this   case,   the   user   must   ascertain   that   

the   materials   in   contact   with   the   product   are   compliant   to   the   relative   Directives.   

The   machine   is   designed   and   manufactured   so   that   the   parts   in   contact   with   the   product   to   be   pumped   can   be   

cleaned    before    each    use;    all    coupling    elements    are    smooth,    without    roughness    or    spaces    where    organic   

materials   can   be   stored;   the   surfaces   in   contact   with   food   products   can   be   easily   cleaned   and   disinfected.   

   

6.2   NON-­‐INTENDED   USE   

The   pump   is   not   suitable   for   pumping   dangerous,   flammable   liquids   or   that   can   generate   a   potentially   explosive   

atmosphere,    except    for    the    ATEX    certified    version.    Should    the    pump    be    used    for    pumping    particularly   

dangerous   chemical   products   for   contact   with   persons   or   things,   it   will   be   necessary   to   check   with   the   supplier,   

the   correct   choice   of   the   metal   materials   and   of   the   elastomers   of   the   pump   parts   that   come   into   contact   with   

the   fluid.   It   will,   however,   be   necessary   for   the   installer   to   create   a   suitable   basin   in   the   operational   area   for   

containing   the   fluid   that   might   leak   due   to   accidental   breaking   of   the   pumping   diaphragm   and   install   remove   

controls    for    the    machine    start-­‐up    and    switch-­‐off    and    draining    pipes    of    the    fluids    collection    basin    to    enable   

maintenance   operations.   

   

   

 

 

 

 

Summary of Contents for Libellula 1/3" aluminium on frame

Page 1: ...EN USE AND MAINTENANCE INSTRUCTIONS SELF PRIMING DIAPHRAGM PUMPS LIBELLULA 1 3 SERIES Read this user manual before installing operating using and maintaining this equipment www caffinipumps it GB...

Page 2: ...OPERATE THE PUMP UNTIL YOU HAVE READ AND UNDERSTOOD THIS MANUAL CAFFINI PUMPS DECLINES ALL AND EVERY LIABILITY FOR DAMAGE DUE TO NEGLIGENCE AND FAILURE TO COMPLY WITH THE INSTRUCTIONS IN THIS MANUAL...

Page 3: ...NG AND TRANSPORT 9 11 STORAGE 9 12 INSTALLATION 10 13 BEFORE START UP 11 14 MAINTENANCE 12 15 SPARE PARTS 13 16 DISPOSAL 13 17 OPERATING PROBLEMS CAUSES AND SOLUTIONS 14 18 FEATURES 15 1 PRESENTATION...

Page 4: ...ed on appropriate plate or punched near the oil introduction plug and the serial and or series number All our products have a 12 month warranty starting from the commissioning date and however for not...

Page 5: ...rs of work The reducer connecting the engine to the connecting rod handle system can be made of light aluminium alloy or in cast iron The transmission gears can be straight or helical teeth with drive...

Page 6: ...DED USE The pump is suitable for handling liquids or muds with solid parts in suspension The pump has dry functioning possibility at indeterminate time The Libellula 1 3 can also be suitable for the t...

Page 7: ...lative distribution of measurement in time and in frequency of the acoustic pressure level of the Libellula 1 3 pump for every required soundproofing intervention 8 SAFETY AND ACCIDENT PREVENTION IMPO...

Page 8: ...It is forbidden to stand under the loads It is forbidden to remove the ATTENTION Safety protections Do not open with the engine running INSTRUCTION FOR THE USE AND MAINTENANCE LIBELLULA 1 3 SERIES ve...

Page 9: ...riate harness Handling must be carried out by specialised staff to avoid damaging the machine and causing accidents to staff The lifting points of the various components must only be used to lift the...

Page 10: ...ted by ball or shutter valve Ensure all joints are perfectly air sealed check the threads the gaskets of the adapters of the ports and of the quick couplings Install the pump as close as possible to t...

Page 11: ...turns in one direction or the other The incorrect rotation direction causes a significant reduction of the flow rate and an incorrect functioning of the reducer The correct rotation direction is that...

Page 12: ...hrough the refuelling plug rod Every three months check the diaphragm and the valves for wear During the winter period with the machine still protect the pump from freezing drain any liquids from insi...

Page 13: ...that facilitates correct installation Spring connecting rod In case of repairing the connecting rod item 218L540I ensure the total length of the same is 305 mm Other spare parts To replace other part...

Page 14: ...suction filter 6 Remove the solid body Low flow rate 1 The rotation speed is too low 2 The delivery pipe is undersized or blocked 3 Too many curves or delivery pipe too long 4 Use of non reinforced c...

Page 15: ...x352x614 mm Net weight 36 kg 79 kg PUMP Type Self priming diaphragm with self lubricated spring or rigid connecting rod Suction ports diameter 3 BSP or DN80 PN10 Delivery ports diameter 3 BSP or DN80...

Page 16: ...CAFFINI CIPRIANO S r l 43044 LEMIGNANO DI COLLECCHIO Parma ITALY Via G Di Vittorio 46 Tel 39 0521 804325 Fax 39 0521 804145 info caffinipumps it w w w c a f f i n i p u m p s i t...

Reviews: