When the test cycle has completed,  the display will show you the meter readings  

and the soft keys will change to: Meter, Cycle, Exit. You can toggle through the  

meter displays or show the cycles by pressing the appropriate soft keys.  

The display will also show you the test status where the text “Dwell” was located.  

If the test passes you will see PASS. If you press the Exit soft key the screen will  

reset back to the set screen.

TEST

SETUP

USING THE 7000 SERIES IN CONSTANT CURRENT MODE

1) Turn ON the OC FOLD parameter.

From the Set screen, press the “<more>” soft key.  In the next screen, press the 

“System” soft key.

In the System Parameters menu, you can use the up or down arrow soft keys to 

highlight the “OC FOLD” parameter.  To change the “OC FOLD” parameter, press 

the “Edit” soft key.

In the next screen, the “OC FOLD” parameter will be highlighted.  Press the 

“Change” soft key to set the highlighted parameter to ON.  Press the “Enter” soft 

key to save changes and then press the “Exit” soft key two times to return to the Set 

screen.

2) Program a current Hi-Limit, which represents the constant current you will 

provide to the load.

From the Set screen,  press the “Edit” soft key.

In the next screen, the Edit Parameters menu, you can use the up or down arrow soft 

keys to highlight the “A Hi-Lmt” parameter.  To change the “A Hi-Lmt” parameter, 

press the “Edit” soft key.

In the next screen, the “A Hi-Lmt” parameter will be highlighted.  Using the Numeric 

Keypad enter the desired current limit.  Press the “Enter” soft key to save changes 

and then press the “Exit” soft key one time to return to the Edit Parameters menu.

3) Program the voltage

From the Edit Parameters menu, use the up or down arrow soft keys to highlight the 

“Voltage” parameter.  To change the “Voltage” parameter, press the “Edit” soft key.

In the next screen, the “Voltage” parameter will be highlighted.  Using the Numeric 

Keypad, enter the voltage value.  The voltage should be set higher than the nominal 

load voltage.  This allows the current to adjust to the Hi-Limit value.  After you enter 

the voltage, press the “Enter” soft key and then press the “Exit” soft key two times to 

return to the Set screen.

Summary of Contents for APT 7000 Series

Page 1: ...input and output cabling TURN OFF the output when making any connections to the load WARNING THIS GUIDE WAS CREATED FOR OPERATORS HAVING SOME FAMILIARITY WITH AC POWER SOURCES AND HIGH VOLTAGE HIGH CU...

Page 2: ...ent s front panel is locked 9 UNIVERSAL AC OUTPUT SOCKET 300 VAC max voltage and 20 A max current Not available on the 7040 model 10 TEST RESET KEY Used to turn ON OFF output voltage or used to reset...

Page 3: ...r the 7008 7016 models To change the fuse unplug the power mains cord and turn the fuse cap counter clockwise to remove fuse The fuse compartment will be exposed Please replace the fuse with one of th...

Page 4: ...ound Output Terminal Earth ground chassis connection for line cord 10c Neutral Output Terminal Neutral screw terminal 10d Line Input Terminal Line input screw terminal for line cord 10e Ground Input T...

Page 5: ...ondition In MANUAL Mode the Rotary Knob on the front panel also becomes active It can be used to adjust voltage or frequency When the instrument is in an idle state it can also be used to edit the Hi...

Page 6: ...xt screen press the Edit soft key and use the up or down arrow soft keys to highlight the Connect parameter Now press the Edit soft key and in the next screen press the Change soft key to toggle the c...

Page 7: ...the Exit soft key two times to return to the Set screen 2 Program a current Hi Limit which represents the constant current you will provide to the load From the Set screen press the Edit soft key In t...

Page 8: ...sults Press the Exit soft key to move back to the set screen VIEWINGTESTRESULTS Figure 4 Results Screen For additional information about these and other key features of the 7000 Series please consult...

Reviews: