SERVICE MANUAL
MAINTENANCE AND TROUBLESHOOTING
2-13
2.6.15 Cut all tie-wraps securing the cable assembly to the air baffle as shown above.
2.6.16 Disconnect both the small enable connector (P1) and the large input power
connector (P2) from each of the power modules as shown above. (Note: There
may be a small amount of RTV securing the P1 connector, and, the locking tabs
of P2 must be depressed before the connector can be removed.)
Summary of Contents for TrueWave TW1750
Page 2: ......
Page 4: ...ii This page intentionally left blank ...
Page 10: ...TABLE OF CONTENTS TW SERIES viii This page intentionally left blank ...
Page 36: ...MAINTENANCE AND TROUBLESHOOTING TW SERIES 2 16 This page intentionally left blank ...
Page 80: ...CALIBRATION TW SERIES 3 44 This page intentionally left blank ...