CALIBRATION
TW SERIES
3-20
Set the TW to 160 Hz.
SOUR:FREQ 160.0
Wait for the DMM to settle and record the voltage as
MEAS3
.
Set the TW to 320 Hz.
SOUR:FREQ 320.0
Wait for the DMM to settle and record the voltage as
MEAS4
.
Set the TW to 500 Hz.
SOUR:FREQ 500.0
Wait for the DMM to settle and record the voltage as
MEAS5
.
Set the TW to 60 Hz and open the output relay.
SOUR:FREQ 80.0
OUTPUT OFF
Calculate the calibration constants:
VALUE1
= 240.0 /
MEAS1
VALUE2
= 240.0 /
MEAS2
VALUE3
= 240.0 /
MEAS3
VALUE4
= 240.0 /
MEAS4
VALUE5
= 240.0 /
MEAS5
Update the remote high range frequency calibration of the TW by sending the following
GPIB string:
CAL
{1,2,3}
:OUTP:REM:HIR:VOLT:FREQCAL
VALUE1 VALUE2 VALUE 3VALUE4 VALUE5
Close the TW’s output relay:
OUTPUT ON
Wait for the DMM reading to settle and record the value as
RDNG1
.
Query the TW’s output put voltage with the GPIB string below and record this value as
MEAS1
.
MEAS
{1,2,3}
:VOLT?