SERVICE MANUAL
CALIBRATION
3-37
Calculate the gain from the collected data:
GAIN
= (
RDGN2
–
RDNG1
) / (
MEAS2
–
MEAS1
)
Update the TW’s gain setting using the GPIB strings below:
CAL
{1,2,3}
:MEAS:LOC:HIR:CURR:GAIN
GAIN
CAL
{1,2,3}
:MEAS:REM:HIR:CURR:GAIN
GAIN
3.26 LOCAL HIGH RANGE WATTS CALIBRATION
Connect the 48 ohm resistor to the output of the TW through the power analyzer. Set
up the power analyzer to measure watts.
Set up the TW to AC coupling, high range, local sense, 6.5 ampere current limit, output
relay closed and 108 volts with the following GPIB programming strings:
OUTP:COUP AC
SOUR:VOLT:RANGE HIGH
SOUR:SENSE LOCAL
SOUR
{1,2,3}
:CURR 6.5
OUTPUT ON
SOUR
{1,2,3}
:VOLT 108
Wait until the power analyzer has stabilized and record the watts reading as
RDNG1
.
Query the TW’s watts using the GPIB string below, and record this value as
MEAS1
.
MEAS
{1,2,3}
:POW?
Program the TW to 268 volts AC using the string below:
SOUR
{1,2,3}
:VOLT 268
Wait until the power analyzer has stabilized and record the watts reading as
RDNG2
.
Query the TW’s watts using the GPIB string below, and record this value as
MEAS2
.
MEAS
{1,2,3}
:POW?
Turn the TW’s output off via the GPIB:
OUTP OFF
Calculate the gain and offset values for updating the TW:
GAIN
= (
RDGN2
–
RDGN1
)/(
MEAS2
–
MEAS1
)
OFFSET
=
RDGN2
–
GAIN
*
MEAS2
Summary of Contents for TrueWave TW5250
Page 2: ......
Page 4: ...ii This page intentionally left blank...
Page 10: ...TABLE OF CONTENTS TW SERIES viii This page intentionally left blank...
Page 36: ...MAINTENANCE AND TROUBLESHOOTING TW SERIES 2 16 This page intentionally left blank...
Page 80: ...CALIBRATION TW SERIES 3 44 This page intentionally left blank...