Connections:

Remote Switch/Release Options:

Initial Setup:

Codes:

Batteries: 

Use only 1.5 volt AA batteries, 4 pieces.

Low Battery:

RED LED will flash five times with beep sound before BLUE LED flashes to signify acceptance of code. Batteries should be replaced as soon as 
this happens.

1.

Remove batteries. Press and hold (#) while connecting the batteries back.
Release after hearing 5 beeps. Within 3 seconds, press (#) keypad 3 times. The BLUE LED will continuously light for 3 seconds and 2 
beeps will be heard.

2.

The unit is now clear of all programmed data and will have reverted to the factory default Master Code 12345.

NOTE: Please follow procedures above exactly otherwise unit will function abnormally. In this case, please repeat the procedure.

No other programming commands will be accepted until default Master Code has been changed.

The unit has 2 sets of terminals for remote release, labeled REM1 and REM2 on the printed circuit board.

REM1 

can be connected to a push button. Pushing the button will cause the unit to unlock. The BLUE LED will light and at the same time a beep 

can be heard twice.

REM2

is intended for alarm systems such as fire alarms. When activated the unit will stay unlocked for 30 minutes and RED LED will flash once 

every 2 seconds while an audible alarm sound will be heard indicating that the unit is in the unlocked condition.

The lock will automatically revert to normal after 30 minutes. If necessary, the Master Code, Sub-Master Code or Manager Code can be 
programmed to revert the unit to normal before the 30-minute period ends.

x

Codes may be 3, 4 or 5 digits long. The length of the Master Code determines all the codes format.

x

Once the numbers of digits are selected, it cannot be changes unless all programming is erased and the default factory settings are re-
loaded.

x

No other programming commands will be accepted until default Master Code has been changed.

MASTER CODE and SUB-MASTER CODE

x

This unit is delivered with the Master Code set to 12345 (default).

x

The Master Code cannot be deleted.

x

Master Code performs all programming functions.

x

Sub-Master Code performs all programming functions except delete or change Master code. 

MANAGERS CODE

x

All Managers Code location ends in zero. (00, 10, 20, 30, 40, 50, 60, 70, 80, 90)

x

Manager Codes are capable of programming and deleting user codes under his Bank. Managers are also capable of accessing the 
next higher Bank until another Manager Code appears.

x

USER CODES

x

Does not have programming privileges. Codes are used for entry only.

SERVICE CODES

x

Service Codes are one-time codes only. It cannot be used again. Once a service code is entered, the unit will unlock but it will 
automatically delete the code.

VALID CODES and PASS TIME (DOOR UNLOCK)

x

Pass Time is the time the unit is unlocked after a valid code is entered.

x

BLUE LED will flash (with 2 beeps) after a valid code is entered.

x

Pass Time also determines the amount of time between two key presses. If the succeeding entry (or key press) was pressed after the
Pass Time, it is now considered as a new entry. Should this happen, wait 5 seconds for the unit to reset by itself then try entering the 
code again.

INVALID CODES

x

The RED LED will flash for .5 seconds with one beep after an invalid code is entered

Summary of Contents for CR3000

Page 1: ...C CAL ROYAL CR3000 Digital Electronic Lock OWNER S MANUAL...

Page 2: ...2 TABLE OF CONTENTS Connections 3 Remote Switch Release Options 3 Initial Setup 3 Codes 3 Keypad Anti Tamper Lockout 4 Tones and LED Indicators 4 Changing the Master Code 4 Add Change Sub Master Code...

Page 3: ...efore the 30 minute period ends x Codes may be 3 4 or 5 digits long The length of the Master Code determines all the codes format x Once the numbers of digits are selected it cannot be changes unless...

Page 4: ...6 1 Press 1 2 3 4 5 9 8 1 2 3 4 5 6 2 3 4 5 6 2 The unit will unlock upon entering the Master Code and will remain unlocked while initiating the program sequence 3 Wait at least 5 seconds before tryi...

Page 5: ...ssage Mode 9 9 971 Key press Sound option Normal 9 9 971 Key press Sound LED Default 9 9 972 Key press Sound Option Click 9 9 972 Key press Sound LED 9 9 973 Key press sound Option LED Only 9 9 981 Ad...

Page 6: ...e is 1 2 3 4 5 and you want to add a new User Code of 3 4 5 6 7 in location 21 1 Press 1 2 3 4 5 1 2 1 3 4 5 6 7 2 The unit will unlock upon entering the Master Code and will remain unlocked while ini...

Page 7: ...and you want to disable a User Code located at location 21 1 Press 1 2 3 4 5 3 2 1 2 User Code at the specified location is disabled Banks are designated as numbers from 0 9 For instance Bank 0 will...

Page 8: ...is added while the unit is in Disable Users mode the new user will overwrite the previous stored code and will automatically be enabled Master Sub Master Code 9 3 EXAMPLE Assuming that the current Ma...

Page 9: ...nager Code is 1 2 3 4 5 and you want to delete all Service Codes 1 Press 1 2 3 4 5 0 2 2 All Service Codes are now deleted Master and Sub Master can enable this feature Once enabled the unit is unlock...

Page 10: ...with a long beep 3 If the Code is not recognized the lock will sound one long beep with a RED LED Note If the Bank or User Number is zero the BLUE LED will not flash and no beep can be heard When prog...

Page 11: ...57 67 77 87 97 08 18 28 38 48 58 68 78 88 98 09 19 29 39 49 59 69 79 89 99 BANKS Banks are designated group of locations in the lock s memory This lock has 10 banks 0 9 and each bank consists of 1 ma...

Page 12: ...ing the proper authorities in order to mitigate the possibilities of harm injury and or damage CAL ROYAL is not liable of either the property or safety of the user s family employees and limits its li...