ELECTRICAL
INSTALLATION
110-Volt Installation
Always follow applicable local, state and federal code and guidelines.
1. Use only a dedicated electrical line with a 20-amp breaker.
2. Do not use an extensions cord.
3. Always use a weatherproof-covered receptacle.
4. Never have your spa within 10’ of the receptacle.
5. Do not bury the power cord.
6. A damaged cord must be replaced before next usage.
7. All 110V spas must have a GFCI (
Figur
e 1
).
This can either be a 20-amp GFCI receptacle or a GFCI cord
and plug kit (CKIT110 - P/N ELE09700086).
8. GFCI plug should be tested prior to every use. To test the GFCI plug version, please follow these easy
instructions.
NOTE
:
Spa should already be plugged in and operational.
A. Press the button marked ‘Test’ on the GFCI. The GFCI will trip and the spa will stop operating.
B. Press the button marked ‘Reset’ on the GFCI. The GFCI will reset and the spa will turn back on.
C. The spa is now safe to use.
W
ARNING
:
IF THE GFCI SHOULD TURN OFF (TRIP) WHILE THE SPA IS IN USE, PRESS
THE RESET BUTTON. IF THE GFCI WILL NOT RESET, UNPLUG THE GFCI AND
CALL YOUR LOCAL SHOWROOM/ DEALERSHIP FOR SERVICE. DO NOT USE
THE SPA.
Electrical Installation
Owner’s Manual
Figure 1
. 1
10V / 20 Amp GFCI Plug.
Summary of Contents for 1100 Electronic Series
Page 12: ...10 ...
Page 78: ...10 ...
Page 118: ...10 ...
Page 161: ...Owner s Manual Page 11 Electrical Installation Owner s Manual Figure 3 GFCI Hook Up ...
Page 219: ...Owner s Manual Page 11 Electrical Installation Owner s Manual Figure 3 GFCI Hook Up ...
Page 282: ...Owner s Manual Page 11 Electrical Installation Owner s Manual Figure 3 GFCI Hook Up ...