9
220 Volt Installation Information
All 220-volt spas are required to have a GFCI breaker and should only be wired by a licensed electrician. To ensure proper
wiring of your GFCI, please follow the wiring diagrams on pages 9 and 10.
1. Always Follow Applicable Local, State, Federal Codes and Guidelines.
2. Your new 220 volt CAL SPA requires a DEDICATED 50 AMP GFCI SERVICE WITH FOUR # 6 AWG COPPER WIRES
This will include a black and red wire for your incoming power, a white wire used for your neutral and a green wire for
your ground.
Note:
#6 AWG wire acceptable on wire run up to 100
’
. Wire run over 100
’
must increase wire to # 4 AWG.
3. Please note that this is the only acceptable electrical wiring procedure. Spas wired in any other way will void your
warranty and may result in serious injury.
Before each use of your spa you should check the GFCI. During this test the spa should be operational.
1. Press the test button on the GFCI. The GFCI will trip and the spa will shut off.
2. Wait 30 seconds and reset the GFCI breaker. This is done by turning the breaker off and then back on. Your spa will be
operational in about 5 seconds.
3. Your spa is now safe to use.
G.F.C.I. Hook-Up
Summary of Contents for 1100 Electronic Series
Page 12: ...10 ...
Page 78: ...10 ...
Page 118: ...10 ...
Page 161: ...Owner s Manual Page 11 Electrical Installation Owner s Manual Figure 3 GFCI Hook Up ...
Page 219: ...Owner s Manual Page 11 Electrical Installation Owner s Manual Figure 3 GFCI Hook Up ...
Page 282: ...Owner s Manual Page 11 Electrical Installation Owner s Manual Figure 3 GFCI Hook Up ...