RUN PMPS PURG AIR
Priming Mode
Each time the spa is powered up, it will
enter Priming Mode. The purpose of
Priming Mode is to allow the user to run
each pump and manually verify that the
pumps are primed (air is purged) and
water is flowing. This typically requires
observing the output of each pump
separately, and is generally not possible
in normal operation.
Priming Mode lasts 4 minutes, but
you can exit it earlier by pressing
any Temp button. The heater is not
allowed to run during Priming Mode.
NOTE: If your spa has a Circ Pump,
it will turn on with Jets 1 in Priming
Mode. The Circ Pump will run by itself
when Priming Mode is exited.
---F - ---C
Water Temperature Is Unknown
After the pump has been running for
1 minute, the temperature will be
displayed.
None
42F TOO COLD
Too Cold - Freeze Protection
A potential freeze condition has been
detected and all pumps and blower are
activated. All pumps and blower are ON
for at least 4 minutes after the potential
freeze condition has ended. In some
cases, pumps may turn on and off and
the heater may operate during Freeze
Protection.
None.
WATR TOO HOT
Water is Too Hot
One of the water temp sensors has
detected spa water temp 110°F (43.3°C)
and spa functions are disabled.
None. System will auto reset when
the spa water temp is below 108°F
(42.2°C). Check for extended pump
operation or high ambient temp.
SFTY TRIP ----
Safety Trip - Pump Suction
Blockage
The Safety Trip error message indicates
that the vacuum switch has closed. This
occurs when there has been a suction
problem or a possible entrapment
situation avoided. (Note: not all spas
have this feature.)
Drain or filter may be covered,
creating a blockage. Clear the
blockage and reset by pressing any
button on the topside panel.
HTR FLOW LOSS ----
Heater Flow Is Reduced
There may not be enough water flow
through the heater to carry the heat
away from the heating element.
Check for low water level, suction flow
restrictions, closed valves, trapped
air, too many closed jets and pump
prime. Heater start up will begin
again after about 1 minute.
HTR FLOW FAIL ----
Heater Flow is Reduced
There is not enough water flow through
the heater to carry the heat away from
the heating element and the heater has
been disabled.
Check for low water level, suction flow
restrictions, closed valves, trapped
air, too many closed jets and pump
prime. Heater start up will begin
again after about 1 minute.
Diagnostic Messages
Summary of Contents for F-1222
Page 1: ...LTR20171005 Rev D 7 20 17 ...
Page 28: ...2017 Fitness Spa LTR20171005 Rev D Operating Your Spa www calspas com 26 ...
Page 29: ...2017 Fitness Spa LTR20171005 Rev D Operating Your Spa www calspas com 27 ...
Page 30: ...2017 Fitness Spa LTR20171005 Rev D Operating Your Spa www calspas com 28 ...
Page 31: ...2017 Fitness Spa LTR20171005 Rev D Operating Your Spa www calspas com 29 ...
Page 32: ...2017 Fitness Spa LTR20171005 Rev D Operating Your Spa www calspas com 30 ...
Page 33: ...2017 Fitness Spa LTR20171005 Rev D Operating Your Spa www calspas com 31 ...
Page 34: ...2017 Fitness Spa LTR20171005 Rev D Operating Your Spa www calspas com 32 ...