2017 Fitness Spa
LTR20171005, Rev. D
Operating
Your Spa
www.calspas.com
19
Message
Meaning
Action Required
HTR MAY BE DRY ----
WAIT ----
Heater May Be Dry
Possible dry heater, or not enough water
in the heater to start it. The spa is shut
down for 15 min.
Check for low water level, suction flow
restrictions, closed valves, trapped
air, too many closed jets and pump
prime. Press any button to reset the
heater start-up.
HTR DRY ----
Heater Is Dry
There is not enough water in the heater
to start it. The spa is shut down.
Check for low water level, suction flow
restrictions, closed valves, trapped
air, too many closed jets and pump
prime. Press any button to reset the
heater start-up.
HTR TOO HOT ----
Heater Is Too Hot
One of the water temp sensors has
detected 118°F (47.8°C) in the heater
and the spa is shut down.
Check for low water level, suction flow
restrictions, closed valves, trapped
air, too many closed jets and pump
prime. Press any button to reset
when water is below 108°f (42.2°C).
PRES BTTN TO RSET
----
Spa Needs To Be Reset
This message may appear with other
messages.
Press any button on the topside
control to reset.
102F SNSR BAL- ANCE
Sensor Balance Is Poor
The temperature sensors MAY be out of
sync by 2°F or 3°F.
Call for service.
SNSR SYNC ---- CALL
FOR SRVC ----
Sensor Balance is Poor
The temperature sensors ARE out of
sync.
Call for service. Note: This message
can be reset from the topside panel
with any button press.
SNSR A ---- CALL FOR
SRVC
SNSR B ---- CALLFOR
SRVC
Sensor Failure
A temperature sensor or sensor circuit
has failed.
Call for service.
NO COMM
No Communications
The control panel is not receiving
communication from the system.
Call for service.
102°T
°F or °C is replaced by °T
The control system is in Test Mode.
Call for service.
STUK PUMP ----
A Pump Appears To Be Stuck ON
Water may be overheated.
POWER DOWN THE SPA. DO NOT
ENTER THE WATER. Call for service.
HOT FALT ---- CALL FOR
SRVC ----
A Pump Appears To Be Stuck ON
A pump appears to have been stuck ON
when spa was last powered.
POWER DOWN THE SPA. DO NOT
ENTER THE WATER. Call for service.
Summary of Contents for F-1222
Page 1: ...LTR20171005 Rev D 7 20 17 ...
Page 28: ...2017 Fitness Spa LTR20171005 Rev D Operating Your Spa www calspas com 26 ...
Page 29: ...2017 Fitness Spa LTR20171005 Rev D Operating Your Spa www calspas com 27 ...
Page 30: ...2017 Fitness Spa LTR20171005 Rev D Operating Your Spa www calspas com 28 ...
Page 31: ...2017 Fitness Spa LTR20171005 Rev D Operating Your Spa www calspas com 29 ...
Page 32: ...2017 Fitness Spa LTR20171005 Rev D Operating Your Spa www calspas com 30 ...
Page 33: ...2017 Fitness Spa LTR20171005 Rev D Operating Your Spa www calspas com 31 ...
Page 34: ...2017 Fitness Spa LTR20171005 Rev D Operating Your Spa www calspas com 32 ...