Diagnostic Messages
Message
Meaning
---F - ---C
Water temperature is unknown. After the pump has been running for
one minute, the temperature will be displayed.
Possible freezing condition
A potential freeze condition has been detected. All water devices are
activated. In some cases, pumps may turn on and off and the heater
may operate during Freeze Protection. This is an operational message,
not an error indication.
The water is too hot
The system has detected a spa water temp of 110°F (43.3°C) or
more, and spa functions are disabled. System will auto reset when the
spa water temp is below 108°F (42.2°C). Check for extended pump
operation or high ambient temp.
Water flow is low
There may not be enough water flow through the heater to carry the
heat away from the heating element. Heater start up will begin again
after about 1 min. See “Flow Related Checks” below.
Water flow has failed
There is not enough water flow through the heater to carry the heat
away from the heating element and the heater has been disabled. See
“Flow Related Checks” below. After the problem has been resolved, you
must press any button to reset and begin heater start up.
The heater may be dry
Possible dry heater, or not enough water in the heater to start it. The
spa is shut down for 15 min. Press any button to reset the heater start-
up. See “Flow Related Checks” below.
The heater is dry
There is not enough water in the heater to start it. The spa is shut down.
After the problem has been resolved, you must clear the message to
restart heater start up. See “Flow Related Checks” below.
The heater is too hot
One of the water temp sensors has detected 118°F (47.8°C) in the
heater and the spa is shut down. You must clear the message when
water is below 108°F (42.2°C). See “Flow Related Checks” below.
Sensors are out of sync
The temperature sensors MAY be out of sync by 2°F or 3°F. Call for
service.
Sensors are out of sync --
Call for service
The temperature sensors ARE out of sync. The fault above has been
established for at least 1 hour. Call for service.
Sensor A Fault, Senor B Fault
A temperature sensor or sensor circuit has failed. Call for service.
Communications error
The control panel is not receiving communication from the System. Call
for service.
°F or °C is replaced by °T
The Control System is in Test Mode. Call for service.
Flow-Related Checks
Check for low water level, suction flow restrictions, closed valves, trapped air, too many closed jets and
pump prime. On some systems, even when spa is shut down by an error condition, some equipment may
occasionally turn on to continue monitoring temperature or if freeze protection is needed.
Preferences
This allows you to set the following preferences for
system operation:
•
Change the temperature between Fahrenheit
and Celsius
•
Change the clock between 12-hour and 24-hour
display
•
Turn periodic reminded (like “CLEAN FILTER”) on
or off
Information
This menu feature is for system information only and
is used mainly for repair and troubleshooting.
Summary of Contents for F-1222
Page 1: ...LTR20171005 Rev D 7 20 17 ...
Page 28: ...2017 Fitness Spa LTR20171005 Rev D Operating Your Spa www calspas com 26 ...
Page 29: ...2017 Fitness Spa LTR20171005 Rev D Operating Your Spa www calspas com 27 ...
Page 30: ...2017 Fitness Spa LTR20171005 Rev D Operating Your Spa www calspas com 28 ...
Page 31: ...2017 Fitness Spa LTR20171005 Rev D Operating Your Spa www calspas com 29 ...
Page 32: ...2017 Fitness Spa LTR20171005 Rev D Operating Your Spa www calspas com 30 ...
Page 33: ...2017 Fitness Spa LTR20171005 Rev D Operating Your Spa www calspas com 31 ...
Page 34: ...2017 Fitness Spa LTR20171005 Rev D Operating Your Spa www calspas com 32 ...