2008 Portable Spa Owner’s Manual
Page 15
LTR20081000, Rev. E
Operating Your Spa
Jets 2
Press the “JETS 2” button once to turn pump 2 on or off
and to shift between low and high speeds if it is a two-
speed pump. If left running, the pump will turn off after
15 minutes.
Option
This is an optional feature. Press the “OPTION” button
to turn the optional equipment on and off. If left on, the
equipment will automatically turn off after 15 minutes.
Light
Press the “LIGHT” button to turn the spa light on and
off and to shift between dim and bright settings if your
light is dimmable. On dim, the control panel will show the
center circle plus one quarter of the light beams. Half of
the light beams will show on medium brightness, and all
of the light beams will show on bright.
Invert
Press the “INVERT” button to change the numbers in the
display to read upside down. Another press returns the
display to the right-side-up position. This enables you to
read the display while you are in the spa.
Locking the Panel
To lock the panel:
Press “TIME”, “JETS 1”, and the “UP” button within
•
three seconds. When locked, the panel will display
“LOCK”. All buttons are frozen except the “TIME”
button.
To unlock the panel:
Press “TIME”, “JETS 1” then the “DOWN” button
•
within three seconds.
Setting the Temperature Lock
To activate the temperature lock:
Press the “UP” or “DOWN” button, “TIME”, “JETS 1”,
•
then the “UP” button within three seconds. The panel
will display “TEMP LOCK” when the set temperature
is locked.
To unlock the set temperature:
Press the “UP” or “DOWN” button, “TIME”, “JETS
•
1”, and then the “DOWN” button.
Circulation Pump
This is an optional feature. The circulation pump will
come on when the system is checking temperature,
during filter cycles, during freeze conditions, or when
another pump is on.
Preset Filter Cycles
There are two filter cycles per day. The start and end
times of each cycle are programmable. To program, set
the time as instructed above, then press “MODE/PROG”
to advance to the next setting (or to exit after the last
setting). The default filter cycles are as follows:
The first filter cycle is automatically activated at 8:00
•
AM and operates the pump until 10:00 AM. The
“FILTER 1” indicator icon will light when filter 1 is
running.
The second filter cycle is automatically activated at
•
8:00 PM and operates the pump until 10:00 PM. The
“FILTER 2” indicator icon will light when filter 2 is
running.
The pump and the ozone generator will run during
filtration. At the start of each filter cycle, the blower will
run on highest speed for 30 seconds to clean out the
air channels. The lowest speed of pump 2 and pump
3 will run for five minutes. In the event of power loss or
shut down, the time of day will need to be reset for filter
cycles to run according to your desired programming.
Clean up Cycle
When the pump or blower is turned on by a button press,
a clean-up cycle begins 30 minutes after the pump or
blower is turned off or times out. The pump and the
ozone generator will run for one hour.
Ozone
This is an optional feature. On most systems, the ozone
generator (if installed) runs during filter cycles (except
when pump 1 is operating at high speed on a non-circ
ulating system) and during clean-up cycles. On some
systems, the ozone generator operates whenever the
pump runs. If your system is configured with the optional
ozone disable feature, the ozone generator will turn off
for one hour any time a function button (“JETS 1”, “JETS
2”, “OPTION” etc.) is pressed.
Freeze Protection
If the temperature sensors detect a drop to 44°F within
the heater, the pump automatically activates to provide
freeze protection. The equipment stays on until four
minutes after the sensors detect that the spa temperature
has risen to 45°F or higher. In colder climates, an optional
additional freeze sensor may be added to protect against
freeze conditions that may not be sensed by the standard
sensors. Auxiliary freeze sensor protection acts similarly
except with the temperature thresholds determined by
the switch and without a four-minute delay in turnoff.