15
If you have tried priming the pump several times
unsuccessfully using the control panel, you can
bleed the air from the pump manually.
Shut off the power to the spa.
1.
Using a Phillips screwdriver, remove the
2.
front panel from the spa and locate the
pump.
Close the gate valve on the discharge side
3.
of the pump (if your spa is installed with
one.)
Turn the bleeder valve counter clockwise
4.
with a small pair of pliers until the air has
been released from the pump.
If this is unsuccessful, loosen the union nut
5.
on side of the pump with channel locks.
When air is bled out, tighten the nut.
Turn on power to the spa and press the
6.
JETS button. If there is still air trapped in
the pump, repeat steps 2 through 5 until
the pump primes.
Bleeding Air from the Pump