2010 Genesis Portable Spa
LTR20101058, Rev. B
Operating
Your Spa
www.calspas.com
9
Message
Meaning
Action Required
OHH
Overheat protection (spa is shut-
down). One sensor has detected
118˚F (48˚C) at the heater.
DO NOT ENTER THE WATER!
Remove the spa cover and allow spa to cool below
107˚F (42˚C). Press any button on the topside dis
-
play to reset spa. If spa will not reset after spa has
cooled, turn off power for approximately 30 seconds
and then turn power back on. If display message is
repeated then shut the power off to the spa and call
your dealer or service organization.
Pr
When your spa is first actuated, it
will go into priming mode.
The priming mode will last for up to four minutes and
then the spa will begin to heat and maintain the water
temperature in the Standard mode.
SL
Indicates heater is in Sleep Mode.
None.
SnA
Snb
Spa is shut down. The sensor that
is plugged into the sensor “A” or
“B” jack is not working.
If the problem persists, contact your dealer or service
organization. (May appear temporarily in an overheat
situation and disappear when the heater cools.)
SnS
Sensors are out of balance.
If this is alternating with the
•
temperature, it may just be a
temporary condition.
If the display shows only this
•
message (periodically blinking),
the spa is shut down.
Contact your dealer or service organization.
ST
Indicates heater is in Standard
Mode.
None.
Summary of Contents for LTR20101058
Page 1: ...LTR20101058 Rev B 9 20 10...
Page 28: ...2010 Genesis Portable Spa LTR20101058 Rev B Appendix www calspas com 26 Cal Spas Chemicals...
Page 29: ...2009 Genesis Portable Spa LTR20091058 Rev B www calspas com...
Page 30: ...2009 Genesis Portable Spa LTR20091058 Rev B www calspas com...
Page 31: ...2009 Genesis Portable Spa LTR20091058 Rev B www calspas com...