RUN PMPS PURG AIR
Priming Mode
Each time the spa is powered up, it will enter
Priming Mode. The purpose of Priming Mode
is to allow the user to run each pump and
manually verify that the pumps are primed
(air is purged) and water is flowing. This
typically requires observing the output of
each pump separately, and is generally not
possible in normal operation.
Priming Mode lasts 4 minutes, but you
can exit it earlier by pressing any Temp
button. The heater is not allowed to run
during Priming Mode.
NOTE: If your spa has a Circ Pump, it will
turn on with Jets 1 in Priming Mode. The
Circ Pump will run by itself when Priming
Mode is exited.
---F - ---C
Water Temperature Is Unknown
After the pump has been running for 1
minute, the temperature will be displayed.
None
42F TOO COLD
Too Cold - Freeze Protection
A potential freeze condition has been
detected and all pumps and blower are
activated. All pumps and blower are ON for
at least 4 minutes after the potential freeze
condition has ended. In some cases, pumps
may turn on and off and the heater may
operate during Freeze Protection.
None.
WATR TOO HOT
Water is Too Hot
One of the water temp sensors has detected
spa water temp 110°F (43.3°C) and spa
functions are disabled.
None. System will auto reset when the
spa water temp is below 108°F (42.2°C).
Check for extended pump operation or
high ambient temp.
SFTY TRIP ----
Safety Trip - Pump Suction Blockage
The Safety Trip error message indicates that
the vacuum switch has closed. This occurs
when there has been a suction problem or
a possible entrapment situation avoided.
(Note: not all spas have this feature.)
Drain or filter may be covered, creating a
blockage. Clear the blockage and reset by
pressing any button on the topside panel.
HTR FLOW LOSS ----
Heater Flow Is Reduced
There may not be enough water flow through
the heater to carry the heat away from the
heating element.
Check for low water level, suction flow
restrictions, closed valves, trapped air, too
many closed jets and pump prime. Heater
start up will begin again after about 1
minute.
HTR FLOW FAIL ----
Heater Flow is Reduced
There is not enough water flow through
the heater to carry the heat away from the
heating element and the heater has been
disabled.
Check for low water level, suction flow
restrictions, closed valves, trapped air, too
many closed jets and pump prime. Heater
start up will begin again after about 1
minute.
Diagnostic Messages
Summary of Contents for PATIO
Page 1: ...LTR20201163 Rev E 3 30 21...
Page 21: ...2020 Portable Spas LAF LTR20201163 Rev E Operating Your Spa www calspas com 19...
Page 22: ...2020 Portable Spas LAF LTR20201163 Rev E Operating Your Spa www calspas com 20...
Page 23: ...2020 Portable Spas LAF LTR20201163 Rev E Operating Your Spa www calspas com 21...
Page 24: ...2020 Portable Spas LAF LTR20201163 Rev E Operating Your Spa www calspas com 22...
Page 25: ...2020 Portable Spas LAF LTR20201163 Rev E Operating Your Spa www calspas com 23...
Page 26: ...2020 Portable Spas LAF LTR20201163 Rev E Operating Your Spa www calspas com 24...
Page 27: ...2020 Portable Spas LAF LTR20201163 Rev E Operating Your Spa www calspas com 25...
Page 75: ...2020 Portable Spas LAF LTR20201163 Rev E Appendix www calspas com 73...
Page 76: ...2020 Portable Spas LAF LTR20201163 Rev E Appendix www calspas com 74...
Page 77: ...2020 Portable Spas LAF LTR20201163 Rev E Appendix www calspas com 75...
Page 78: ...2020 Portable Spas LAF LTR20201163 Rev E Appendix www calspas com 76...
Page 79: ...2020 Portable Spas LAF LTR20201163 Rev E Appendix www calspas com 77...