Size
1.7 x 2.5 x 1”, (43 x 64 x 25mm)
Weight
1.8 oz, (51 g)
Operating Temperature
-30° C to 75° C
Storage Temperature
-40° C to 85° C
Humidity
0% to 95% relative humidity, at 50° C non-condensing
Shock and Vibration
SAE Test: SAE J1455 Compliant
Mil Standard 202G and 810F Compliant
Ground vehicle environment with associated shock and vibration
Electromagnetic Compatibility (EMC/EMI)
SAE Test: SAE J1113 Parts 2, 12, 21 and 41 Compliant
FCC Part 15B Compliant
Industry Canada Compliant
EMC compliant for a ground vehicle environment
Operating Voltage Range
12V Vehicle systems
Power Consumption
Active Standby: 140mA at 12VDC
Sleep on Network: 11mA at 12VDC
Deep Sleep: 3mA at 12VDC
GPS
50 channel WAAS capable GPS Receiver
2m CEP (with SBAS)
-162 dBm tracking sensitivity
Communications (Comm)
Quad Band Class 12 GPRS Modem
850 MHz (Class 4) – 2W
900 MHz (Class 4) – 2W