 1. Basic Inroduction

Product User Manual

5

6

3)  For the automotive module or portable module application, appropriate measures 

of shock absorbing shall be taken.

4)  Leave enough adequate space above the battery module inner the battery box ,to 

connect the battery management system harness line,  also for better heat 

dissipation.

5)  When batteries are integrated into group, insulated protective measures shall be 

taken; 

6)  When the communication system is installed, it should be checked whether the 

feeder line connected to the grid is flow in advance, including each node, the 

socket connection, in order to avoid the open or short circuit faults.

2.5 Battery Connection Requirements

Electrical connection should comply with the relevant national electrical installation 

practices.

1)  Be careful when connecting the batteries, do pay attention to safety of high 

voltage to avoid battery short circuit;

2)  Quick connectors shall be set between battery modules, higher protectionlevel of 

power cord, plug and socket connectors and charging plugs and sockets shall be 

chose.

3)  When connecting the battery management system with batteries, copper and 

aluminum terminal surface of the battery shall be sanded (180 to 240 mesh is 

recommended for sanding, nickel terminal pole is prohibited to sand) to remove 

the oxide layer, thus reducing the contact resistance. If the copper bus bar surface 

is not processed, the contact surface of bus bar and connectors should be 

polished.

4)  Battery pole bolts must be tightened so as to avoid increasing contact resistance 

caused by poor contact. As the positive pole of battery is made by aluminum 

material, avoid excessive force when tightening the pole bolt to avoid screw 

thread slipping. For tightening torque

 please refer to content 2.6;

5) Make sure the welding and crimping of BMS acquisition line for voltage terminals, 

and connection of wiring harness reliable, avoid affecting voltage signal sampling 

accuracy due to poor contact. Insulating bush covering the terminals should not 

be too long so as to wrap the terminals.

6) The voltage acquisition line length should be appropriate. If the voltage acquisition 

line is too long, voltage on it will drop excessively

which can bring large error for 

voltage measurement.

Battery terminal pole sanding

Bus bar sanding

2.6 Operation tools

1)  During the process of battery connection, insulating gloves must be worn.

2)  The socket wrench, fixed wrench and screwdriver and other tools used for opera-

tion must be gone through rigorously insulating treatment. The operators are 

prohibited to carry metal items such as key chains, watches, necklaces and so on;

3)  When the terminal voltage of the connected grouping products is greater than 

24V, insulating gloves which can withstand voltage higher than the voltage of the 

entire group of connected systems shall be worn.

4)  When tightening the bolts, it is recommend using adjustable torque wrench in 

5-30N•m  range,  the  recommended  tightening  torque  values  corresponding  to 

specified bolts is shown in the following table.

2.7 Power system maintenance period and measures

1)  In a routine systematic check and detailed record on the power system usage, as well as the work of BMS and charger, detect 

hidden dangers and solve problems in time.

2)  Regularly check the connecting bolts fuses, contactors and fuses, as well as the degree of tightening for all the bolts connecting 

the battery poles.

3)  Regular inspect the connection reliability of all power connectors and electrical connectors, and check the insulation of the 

electric circuit and connection of cables and busbars.

4)  Check the battery voltage and current differences between BMS detected and data actually measured, and check BMS signal 

acquisition accuracy and check whether the SOC calculation precision calibration is required;

5)  Check the consistency of the whole set of batteries. If static or dynamic voltage difference of the battery is too large, please 

operate as troubleshooting steps.

2.8 Common troubleshooting methods for power system 

Tools insulating treatment

Insulating gloves

No.

1

2

3

4

Terminal bolt specification

M5

M6

M8

M14

recommended tightening torque

N·m

10

9

14

24

Note: Data shown on the table are manual measurement experience; If you 

purchase by yourselves, we recommend bolt material A2-70; Tightening 

torque can be referred to the recommended values corresponding to the 

thread diameter above.

No.

1

2

3

4

5

Common Fault

Failure Cause

Approach

Note: 1. The examination and treatment for the power system should be based on system technology agreement; 

 

2. The examination for the power system requires trained personnel, and pay attention to the safety protection against high 

voltage and devices wounding during examination ; 

 

3 .If they can not determine the cause of failure, contact our after-sales personnel promptly.

Voltage acquisition failure (BMS software problems, poor 

socket contact, acquisition line connection error, loose 

connections of battery terminals, etc.)

Temperature acquisition abnormal

acquisition device 

damage, bad connectors, pole connections loose)

Thermal management system abnormal (fan or heating 

device does not start, duct blockage, etc.)

Battery itself reason(terminal severe oxidation, internal 

reasons)

Abuse like over charge, over discharge; environmental 

reasons like high temperature, high humidity, ultra low 

pressure

upside down and other external cause

tightening torque is too large, tightening operation not 

standard

Battery fault

State of charge is inconsistent, internal 

reasons

Abnormal voltage

Abnormal temperature

Battery bulging

Battery leakage

Terminal slippery

1. Investigating the fault and eliminated;

2. If the fault does not exist, it may be 

the batteries fault.

Investigation of the cause of the fault 

and eliminate

Check the thermal management system

repair or replace

Troubleshooting and contact after sales

Troubleshooting and contact after sales

Troubleshooting and replace

repair or replace

Summary of Contents for CA100

Page 1: ...ection components installation 17 Product User Manual China Aviation Lithium Battery Co Ltd CALB Headquarter No 66 North Binhe Road High Tech Zone Luoyang Henan China 471003 Tel 86 0379 6069 7962 Fax 86 0379 6069 7995 http www calb cn http en calb cn ...

Page 2: ...ment research and production and certifications to enter into international markets including CE RoHS and UN38 3 transportation certification CALB and products have high reputa tion and influence in home and abroad markets Developing green energy is our common history mission Under the strong support of leaders at all levels and partners CALB will take the idea of AVIC Aviation to serve the countr...

Page 3: ...ing chair battery The charge and discharge mechanism of lithium ion battery can be described as the following chemical formula take lithium iron phosphate for example Lithium ion battery charge and discharge diagram Caution I A BMS battery management system or battery protection system must be used under any circumstance when using or storing battery to ensure the batteries are used under normal c...

Page 4: ...between 10 90 DOD according to the principle of low depth of charge and discharge 8 Screwing the battery terminal is forbidden without permission 9 Damaging the battery safety valve is forbidden without permission As the case of CAM series battery is metal it is strongly recommended to install a protector when installing CAM series batteries with the specific installation program to ensure the bat...

Page 5: ...it is recommend using adjustable torque wrench in 5 30N m range the recommended tightening torque values corresponding to specified bolts is shown in the following table 2 7 Power system maintenance period and measures 1 In a routine systematic check and detailed record on the power system usage as well as the work of BMS and charger detect hidden dangers and solve problems in time 2 Regularly che...

Page 6: ...be prevented from mechanical shock or stress non battery exposure and rain 6 Develop a tracking record of voltage resistance for inventory batteries check the stock battery voltage resistance every three months and make detailed records 7 Conduct a full charge discharge test inventory every six months for inventory batteries at a charge and discharge rate of 0 3C and make detailed records 3 1 Pers...

Page 7: ...ignated locations within the shortest possible time in mainland China only Time requirements For customers in China mainland CALB will response in two hours within the city in 24 hours within the province three working days or within 30 minutes to give customers a clear answer and reach to the customers within the appointed time outside the province For international customers CALB will response i...

Page 8: ... 90 0 C 45 C 20 C 55 C 20 C 45 C 20 C 25 C 70 2C 1C 2C Charging time Installation for CAM Series single battery can be followed by four steps First Install lower protector as figure 2 Installation requirements Depress the battery into the lower protector from up to down by force to ensure the battery no slant and below protector wrapping the bottom of the battery no loose connection between protec...

Page 9: ...rouping separators by one side and clamp the battery by the snap on both sides without falling down The grouping separator should be fitted with the upper and lower separator edge without warping Lower protector Grouping separator Figure 3 Step 3 Install upper protector as figure 4 Installation requirements Push the battery grouping separator by one side and clamp the battery by the snap on both s...

Page 10: ...rwise it will affect the screw installation causing protectors scratch Install the pole protectors promptly after connecting the bus bars and prevent cascading battery packs from short circuit caused by foreign objects The integrated packs should be placed on a workbench with flat and dry surface The completion of battery packs protector installation is shown above Step 2 Select screws of appropri...