C
onstruCtion
M
aster
P
lus
eZ
15
Fourth press of
e
:
(Volume answer format preference)
VoLUMe UnitS Std. 0.
v
VoLUMe UnitS CU Yd 0.
v
VoLUMe UnitS CU Feet 0.
v
VoLUMe UnitS CU M 0.
v
(repeats options)
VoLUMe UnitS Std. 0.
Fifth press of
e
:
(
Stair Riser Height Preference
– Target gets calculation as close
to Target Riser Height as possible. Max calculation will not exceed
Maximum Riser Height.)
tarGet riSer hGht. 0.
v
MaX riSer hGht. 0.
v
(repeats options)
tarGet riSer hGht. 0.
Sixth press of
e
:
(
Rake Preference
–
Sets Rake-Wall Stud sizes to Descending or
Ascending order.)
deSCendinG raKe 0.
v
aSCendinG raKe 0.
v
(repeats options)
deSCendinG raKe 0
Seventh press of
e
:
(
Jack Preference
– Sets Jack Rafters to Descending or Ascending order)
deSCendinG JaCK 0.
v
aSCendinG JaCK 0.
v
(repeats options)
deSCendinG JaCK 0.
Eighth press of
e
:
(
Jack Alignment Preference –
Sets Jack Spacing to On-center or Mate)
JaCK aLiGnMent oC 0.
v
JaCK aLiGnMent Mate 0.
v
(repeats options)
JaCK aLiGnMent oC 0.
Ninth press of
e
:
(
Run/Span Preference –
Span is the length of a top plate or twice the length
of the Run)
rUn/SPan SettinG rUn 0.
v
rUn/SPan SettinG SPan 0.
v
(repeats options)
rUn/SPan SettinG rUn 0.
Tenth press of
e
:
(Linear Meters format Preference)
Linear MeterS FiX M 0.000
v
Linear MeterS aCt. M 0.
v
(repeats options)
Linear MeterS FiX M 0.000
Eleventh press of
e
:
(Degrees format Preference)
deGreeS — FiXed 0.°
v
deGreeS — aCtUaL 0.00 °
v
(repeats options)
deGreeS — FiXed 0.00 °
Twelfth press of
e
:
(Order of Entry Preference)
order oF entrY Math 0.
v
order oF oPer Math 0.
v
(repeats options)
order oF entrY Math 0.
elliptical arch Function
required entries
Possible Solutions
Height
Width
Stud On-Center Spacing
•
Default value: 16″
Stud Location
•
Default setting: Outside the Arch*
Center to Foci Length
Foci to Foci Length
String Point-to-Point Length
String Loop Length
Arch Area
Center Stud Length
Other Stud Lengths
optional entries
Base Height
* Stud Position or Location refers to the placement of the studs:
•
Entering
1
calculates studs located Outside of the Arch
•
Entering
2
calculates studs located Inside of the Arch.
Note:
All Elliptical Arch solutions are based on 180° arch angles.
Solve for an Elliptical Arch that is 5′ high, 15′ wide with studs Outside the Arch:
1. Clear Calculator:
OOO
2. Go to Extras function:
CN
(If necessary, continue pressing
N
until
eLLiPtiCaL arCh
displays.)
3. Start Elliptical Arch function:
e
4. Enter Elliptical Arch Height:
5fe
5. Enter Elliptical Arch Width:
15fe
6. No Base Height:
e
7. Accept 16″ Stud On-Center Spacing default value:
e
8. Accept default Stud Position (Outside the Arch) and solve for Elliptical Arch:
e
Center to FoCi Lnth
5 Feet 7–1/16 inCh
e
FoCi to FoCi Lnth
11 Feet 2–3/16 inCh
e
StrinG Pt. to Pt. Lnth
15 Feet 0 inCh
e
StrinG LooP Lnth
26 Feet 2–3/16 inCh
e
arCh area
235.61945 SQ Feet
e
Center StUd Lnth
0 Feet 0 inCh
e
StUd Pair LenGth Ø1
0 Feet 0–15/16 inCh
e
StUd Pair LenGth Ø2
0 Feet 3–15/16 inCh
e
StUd Pair LenGth Ø3
0 Feet 9–1/4 inCh
e
StUd Pair LenGth Ø4
1 Feet 5–13/16 inCh
e
StUd Pair LenGth Ø5
2 Feet 8–1/2 inCh
e
StUd Pair LenGth Ø6
5 Feet 0 inCh
Crown Molding Function
required entries
Possible Solutions
Wall Corner Angle
•
Default value: 90°
Spring Angle
•
Default value: 45°
Miter Angle
Bevel Angle
Solve for Crown Molding with a Corner Angle of 60
º
and a Spring Angle of 38
º
:
1. Clear Calculator:
OOO
2. Go to Extras function:
CN
(If necessary, continue pressing
N
until
CroWn MoLdinG