background image

Please take the time to read this booklet carefully, as it will provide you with the information you will need to ensure 

the safe, secure, and timely installation of your new spa. The following sections are guidelines on how to prepare for 

delivery and set-up of your new spa. Specifically covered are site selection, delivery access, ground preparation, and 

electrical requirements.
Remember to carefully read the Owner’s Manual that accompanies your spa, and to complete the warranty card 

within 10 days of delivery. These items, along with other valuable information, will be found in the Owner’s Package 

which has been placed in the equipment compartment of your spa, where you will also find a serial number.

WATKINS WELLNESS

 reserves the right to change features, specifications and design without notification and 

without incurring any obligation.

DATE PURCHASED:  _________________________________________________________________

DATE INSTALLED: ___________________________________________________________________

DEALER: ___________________________________________________________________________

ADDRESS: __________________________________________________________________________

TELEPHONE: _______________________________________________________________________

In most cities and counties, permits will be required for the installation of electrical circuits or the construction of 
exterior surfaces (decks and gazebos). In addition, some communities have adopted residential barrier codes which 
may require fencing and/or self-closing gates on the property to prevent unsupervised access to a pool (or spa) by 
children under 5 years of age. Your Caldera

®

 spa is equipped with a locking cover that meets the ASTM F1346-91 

Standard for Safety Covers and as a result, is usually exempt from most barrier requirements. As a general practice, 
your local Building Department will inform you of any applicable barrier requirements at the time a permit is obtained 
for the installation of an electrical circuit. Your 

CALDERA

 dealer can provide information on which permits may be 

required.

Vacanza

®

 Series Pre-Delivery Instructions

Summary of Contents for Vacanza Series

Page 1: ...___________________________________________________ DEALER ____________________________________________________________________________ ADDRESS ________________________________________________________...

Page 2: ...ovide a good grip when wet Proper drainage is essential to prevent a build up of water around the spa When building a new room for the spa it is recommended that a floor drain be installed The humidit...

Page 3: ...n unlevel spa Remember placing the spa on grass or dirt may increase the amount of debris which is inadvertently brought into the spa water on the user s feet If you are purchasing a deck package or g...

Page 4: ...to roll the spa to its installation site About ten percent of the time a crane is the only way to install the spa by lifting it to its final destination If the spa has to be taken off of the cart to...

Page 5: ...structurally sound deck able to support the dead weight found in the spa specification chart IMPORTANT The PALATINO must not be shimmed in any manner PALATINO NOTE All dimensions are approximate measu...

Page 6: ...concrete pad or structurally sound deck able to support the dead weight found in the spa specification chart IMPORTANT The MARINO VANTO must not be shimmed in any manner MARINO VANTO NOTE All dimensi...

Page 7: ...r structurally sound deck able to support the dead weight found in the spa specification chart IMPORTANT The TARINO must not be shimmed in any manner TARINO NOTE All dimensions are approximate measure...

Page 8: ...n or pathway decisions NOTE WATKINS WELLNESS recommends that the AVENTINE be installed on a minimum 4 10 cm thick reinforced concrete pad or structurally sound deck able to support the dead weight fou...

Page 9: ...if an electrical outlet with a cover is required for your installation If it is a suitable outlet cover may be purchased from your authorized CALDERA dealer 115 Volt Electrical Requirements The TARIN...

Page 10: ...ACK L1 8 AWG GREEN GROUND 8 AWG WHITE NEUTRAL 50A WITHIN SIGHT OF THE SPA THE SUB PANEL MUST BE MORE THAN 5 FEET DO NOT EXCEED 50 FEET WITH GFCI BREAKERS 50A SUB PANEL L2 GRD L2 HOT 8AWGRED L1 HOT 8AW...

Page 11: ...wire electrical service two line voltages one neutral one ground from the main electrical service panel to the subpanel The grounding conductor must be at least 8 AWG Your electrician should mount th...

Page 12: ...ater high limit General spa operation maintenance orientation ______________ Inspect the spa cover place on spa and install cover locks ______________ Review winterizing instructions ______________ Re...

Page 13: ...Page 13 NOTES...

Page 14: ...Pre Delivery Instructions NOTES Page 14...

Page 15: ...NOTES Page 15...

Page 16: ...105 lbs per square foot 115 volt 20 amp Dedicated GFCI protected cord or 230 volt 50 amp Single phase GFCI circuit F o o t p r i n t d i m e n s i o n s H e i g h t E f f e c t i v e fi l t e r a r e...