Tahatian
Page 29
e
lectrIcal
r
eQuIrementS
IMPORTANT:
Fill the spa with water before turning on the power.
Your
CALDERA
spa has been carefully designed to give you
maximum safety against electrical shock. Connecting the spa to an
improperly wired circuit will negate many of the spa’s safety features.
Improper wiring may also cause electrocution, risk of fire, and other
risks of injuries. Please read and follow the electrical installation
requirements and instructions for your specific spa model completely!
All
CALDERA
spa models, are equipped with a power indicator
(
CALDERA
Logo orange light) which, in addition to showing the spa
has power to it, has a diagnostic function as well. It will begin blinking
if the heater high-limit thermostat has tripped. If the power indicator
light is blinking, follow the instructions in the Troubleshooting section
to identify and correct the cause. The power indicator will stop blinking
once the problem has been corrected. The Power and Ready indicator
lights on the control panel also provide the same diagnostic function.
230 VOLT PERMANENTLY
CONNECTED
CALDERA
spas must be wired in accordance with all applicable local
electrical codes. All electrical work should be done by an experienced,
licensed electrician. We recommend the use of appropriate electrical
conduit, fittings, and wire for all circuits.
The diagram on the following pages illustrates how to wire the
spa models:
• An electrical subpanel containing two GFCI breakers is included with
each 230 volt spa. We recommend that this subpanel be used to
supply power to the spa.
• The subpanel requires a 50 amp, single phase, 230 volt, four wire
service (two line, one neutral, one ground).
The grounding conductor must not be less than #10 AWG. Refer to
local codes and to NEC 250-122 (table).
NOTE
: The
CANTABRIA
will require an additional 20 amp breaker
in order to operate the heater and the Lounge seat (jet pump 3) at
the same time. Without the additional 20 amp breaker, the heater will
NOT operate while the jets in the lounge (jet pump 3) are on.
• Mount the subpanel in the vicinity of the spa, but not closer than 5
feet (1.5 m) away, in accordance with all local codes. (N.E.C. 680-38
to 41-A-3)
• Open spa using Door Panel Removal instructions (page 35).
• Insert power wires into spa from either side towards the bottom front,
you will find a plastic cap attached to spa.
• Once your spa has been filled with water, turn it on and test all of
the circuit breakers.
IMPORTANT:
If both breakers immediately trip, verify that the wires are
correctly connected. Each breaker should be tested prior to each use.
Here’s how:
1. Push the “TEST” button on each GFCI breaker, and observe it
click OFF.
2. Wait 30 seconds, then push the breaker switch to the OFF (down)
position (to ensure that it has completely disengaged), then push
the breaker switch to the ON (up) position. If you don't wait 30
seconds, the spa’s power indicator may continue to blink – try
again.
If any of the GFCI breakers fails to operate in this manner, your spa
may have an electrical malfunction, and you may be at risk of electrical
shock. Turn off all circuits and do not use the spa until the problem has
been corrected by an authorized service agent.
WARNING:
Removing, or bypassing any GFCI breaker will result
in an unsafe spa and will void the spa’s warranty.
7
2
3
4
5
6
8
1
EQUIPMENT COMPARTMENT
The illustration below is to be used as a reference only (your spa may look different). The equipment compartment is located behind the front panel of the
spa below the Main Control Panel.
1. Jet pump*
2. EnergyPro
®
heater
3.
ENERGY PRO
Circulation Pump
4. Advent
®
Control Box
5. Ozone Generator (optional)
6. Bonding terminal
7. Bluetooth Music (optional)
8. Subwoofer (optional)
1
* There are 3 jet pumps located in the Cantabria equipment compartment, only 2 are shown in illustration above.
Electrical Requirements
Summary of Contents for CalderaSpas Utopia Series
Page 1: ...2 0 2 2 O W N E R S M A N U A L Utopia Series ...
Page 39: ......