11
WARNING
: Removing or bypassing any GFCI breaker will result in an unsafe spa and will void the spa’s warranty.
IMPORTANT
: Should you ever find the need to move or relocate your Caldera
®
spa, it is essential that you understand and apply these installation requirements. Your
Caldera spa has been carefully engineered to provide maximum safety against electric shock. Remember, connecting the spa to an improperly wired circuit will negate
many of its safety features.
NOTE
: Long wiring runs may require larger-gauge wire than stated.
ELECTRICAL INSTALLATION
System Ground Terminal
GRD
WARNING!
THE EXACT PHYSICAL LOCATION OF THE TERMINALS ON THE GFCI BREAKER
WILL VARY BETWEEN MANUFACTURERS. CONNECTING THE HOT WIRE TO THE
NEUTRAL TERMINAL WILL CAUSE IRREVERSIBLE DAMAGE TO THE CONTROL BOX.
** Refer to NEC 250-122 (table)
*PROVIDED WITH SPA.
NOTE: ALL WIRING SHOULD BE COPPER.
230 Volt Permanently Connected
** Refer to NEC 250-122 (table)
NOTE: The wire connections to GFCI breakers are for reference only. Always ensure the white neutral wire is connected to the load neutral of the 30 amp breaker.
**
**
230V WIRING ACCESS
OPENINGS ON RIGHT& LEFT
HAND SIDE
DOOR
CONTROL BOX
POWER CONNECTION ACCESS
DRAIN