FILTER MAINTENANCE

At least once a week, check and clean the skimmer basket and weir to ensure proper filter
flow. Remove leaves, foreign matter, and debris. It is very important to keep your spa filter
cartridge clean and free of particles to ensure proper water flow. A clean filter permits the
hydrotherapy system to function properly and also allows more efficient filter cycles.
Depending on how frequently your spa is used, we recommend cleaning the spa filter
cartridge every four weeks. If this is not done, the filter may clog and restrict water flow,
which causes improper filtration and poor jet performance.

IMPORTANT: 

The frequency and duration of use, and the number of occupants all

contribute to determining the appropriate time between filter cleanings. More use means
that more frequent filter cleanings will be required.

FILTER CARTRIDGE REMOVAL AND
CLEANING INSTRUCTIONS

Turn the power to the spa off, then proceed as follows:

1.  Push down slightly and turn filter basket counter-clockwise to unlock, then pull out the

basket and weir.

2.  Carefully pull up the filter cartridge and bring it out of the spa. 

3.  Always clean the filter using a filter degreaser to remove mineral and oil build-up.

Simply soak the filter in the degreaser (according to the package directions), then
place the filter on a clean surface and spray until clean using a garden hose. It may be
necessary to rotate the filter while spraying to remove any debris lodged between the
filter pleats.

4.  To return basket and weir, insert and rotate clockwise to lock into position. Then, turn

spa’s power back on.

NOTE: 

Replacement filter cartridges are available from your Caldera

®

dealer. Refer to the

back of this manual to determine the appropriate size for your spa.

DIVERTER VALVE MAINTENANCE

If your spa’s diverter valves become difficult to turn, it is likely that sand or grit has become lodged inside the valve body. It is very important that this debris is removed
as soon as possible to avoid damage to the valve. To accomplish this, follow this procedure:

1. Turn off power to the spa.

2. Remove the diverter valve’s handle by pulling upward while rocking it back and forth.

3. Unscrew the cap ring.

4. Remove the valve body by pulling it upward.

5. Wipe the valve body and the interior walls of the valve clean.

6. Lubricate the o-rings with a waterproof lubricant available from your Caldera dealer.

7. Reassemble the valve and turn on power to the spa.

VERSASSAGE

®

JETS MAINTENANCE

If you notice that the VersaSsage jets spin slower than when the spa was new, or the jets are sticking, the cause maybe built-up of deposits inside the jet bearings. To
remove the deposits, use the following instructions:

1.  With the spa off, rotate the VersaSsage jet face counter-clockwise until it stops.

2.  Once the face stops rotating, use a little extra force to rotate the face even more counter-clockwise past the locking position until it stops. Pull face away from the

spa.

3.  After flushing the bearings inside the body with water, spin the rotating nozzle, it should spin very freely. If it does not, place the bearing end in a cup of vinegar (the

vinegar will soften any deposits). Leave soaking overnight. The next day, flush with water and repeat the spin test. 

NOTE

: If it still doesn’t spin freely then a second night of soaking is required. Replace jet if the bearing still does not spin. 

4. To replace, position the cutout at the back end of the face body downward and push the face body back into the jet fitting. Slightly rotate face body in either

direction until you feel the body align with the fitting, then press firmly on the face. Once seated, rotate the face clockwise using a little extra force to overcome the
locking position. If the face does not rotate, remove and rotate face 180° and repeat this step. Turn the jet pump on, the VersaSsage jet should spin freely.

MAINTENANCE

FLOATING WEIR

BASKET

FILTER 
CARTRIDGE

STANDPIPE

PLEATS

MONARCH

®

SILVER ION
PURIFIER

Summary of Contents for Hawaiian

Page 1: ...MooreaTM Hawaiian Martinique Kauai Paradise Series Owner s Manual...

Page 2: ...LEPHONE ________________________________________________ SPA MODEL SERIAL NUMBER ______________________________ COVER SERIAL NUMBER ____________________________________ In most cities and counties per...

Page 3: ...IONS Locking Features 19 Main Control Panel Buttons and Display 20 EQUIPMENT COMPARTMENT Jet Pump Side 22 Controls Side 23 MAINTENANCE Filter Maintenance 24 Filter Cartridge Removal and Cleaning Instr...

Page 4: ...ructions per electrical configuration 230 volt permanently installed models A ground terminal is provided on the terminal block located inside the control box To reduce the risk of electric shock conn...

Page 5: ...use the spa Health problems affected by spa use Pregnant women should consult a physician before using spa Persons suffering from obesity or with a medical history of heart disease low or high blood p...

Page 6: ...r authorized Caldera dealer Many problems can easily be diagnosed over the telephone by an Authorized Service Technician SAVE THESE INSTRUCTIONS SITE PREPARATION You probably have a spot picked out fo...

Page 7: ...r regularly to ensure proper levels of sanitizers pH and other water care requirements Drain clean and refill your spa with fresh water on a regular schedule and in accordance with this owner s manual...

Page 8: ...ersaSsage Jet 7 Euphoria Jet 8 Grab Rail 9 Diverter Valve 10 Drain 11 Light 12 Ozone Jet 13 Control Panel 14 Pillow 15 Filter Compartment 16 Water Fall 17 Water Fall Valve 1 1 1 3 5 6 5 8 10 10 11 13...

Page 9: ...t 6 MagnaTM Jet 7 Euphoria Jet 8 Diverter Valve 9 Drain 10 Light 11 Ozone Jet 12 Control Panel 13 Pillow 14 Filter Compartment 15 Grab Rail 16 Waterfall 17 Waterfall Valve 1 3 4 4 4 10 7 13 13 13 13 2...

Page 10: ...re Sensor 4 MagnaSsageTM Jet 5 MagnaTM Jet 6 VersaSsage Jet 7 Grab Rail 8 Diverter Valve 9 Drain 10 Light 11 Ozone Jet 12 Control Panel 13 Pillow 14 Filter Compartment OVERHEAD VIEW PARADISE MARTINIQU...

Page 11: ...al Jet 3 Euro Pulse Jet 4 VersaSsage Jet 5 Grab Rail 6 Diverter Valve 7 Drain 8 Light 9 Ozone Jet 10 Control Panel 11 Pillow 12 Filter Compartment 13 Temperature Sensor OVERHEAD VIEW PARADISE KAUAI MO...

Page 12: ...ust be attached to the LOAD neutral on the 230 volt 30 amp breaker not to the neutral bus bar in the subpanel The WHITE neutral wire coming from the breaker itself is already connected to the neutral...

Page 13: ...y require larger gauge wire than stated ELECTRICAL INSTALLATION System Ground Terminal GRD WARNING THE EXACT PHYSICAL LOCATION OF THE TERMINALS ON THE GFCI BREAKER WILL VARY BETWEEN MANUFACTURERS CONN...

Page 14: ...ty TA to 125 ppm Calcium Hardness CH to 150 ppm then spa water pH to between 7 4 and 7 6 These procedures are listed in the Water Quality and Maintenance section OPERATION NOTE Adjusting the Total Alk...

Page 15: ...ve located on the front interior wall counterclockwise The flow is regulated by turning the waterfall valve to the desired position AIR CONTROLS Each jet system has its own air control These allow you...

Page 16: ...low you to regulate the force of the massage Rotate the fascia ring clockwise to reduce the force or counter clockwise to increase the force Notice that turning off the flow to some jets increases the...

Page 17: ...in mid position activates both Jet Pump 1 Systems 1 and 2 Jet Pump 2 diverter in mid position activates both Jet Pump 2 Systems 1 and 2 PARADISE MOOREA TM Jet Pump 2 Jet System 2 Waterfall Positioned...

Page 18: ...ge jets Jet Pump 2 Jet System 1 6 Sole Soothers Waterfall Located in Ultra Massageseat front right 3 VersaSsage jets 2 Euro Directional jets Jet Pump 2 Jet System 2 1 Euphoria jet in footwell Ultra Ma...

Page 19: ...Jet Pump 2 Jet System 1 Located in Ultra Massagelounge front 6 Sole Soothers 2 Euro Directional jets 3 VersaSsage jets Combination Jet System Jet Pump 2 diverter in mid position activates both Jet Pu...

Page 20: ...eat 8 Euro Directional jets 2 Euro Pulse jets Jet Pump Jet System 2 Located in Ultra Massagelounge 6 Sole Soothers 3 VersaSsage jets 2 Euro Directional jets Located in LumbarSsage lounge 4 Euro Direct...

Page 21: ...nation of buttons Once enabled a lock will remain active until the specific button combination is applied to disable the lock Even if power is disconnected from the spa and soon thereafter reapplied s...

Page 22: ...of the spa water press the TEMP Each time the button is pressed the set temperature display will decrease by one degree If the button is held down the set temperature display will decrease by one degr...

Page 23: ...ater temperatures low enough for comfort Upon switching to the ON mode the heater will immediately shut down while the circulation pump which can add heat to the water through normal operation will re...

Page 24: ...Included with the Optional Monarch CD Ozone Generator kit 4 Unions 5 Air Blower 6 Light 7 Temperature Sensor 8 Pump Drain Plug 1 2 3 5 2 3 3 6 1 Kauai Moorea Hawaiianand Martinique NOTE Martinique doe...

Page 25: ...UIPMENT COMPARTMENT A B C D A Advent Control Box System B EnergyPro Circulation Pump C EnergyProFlow Through Heater D Monarch CD Ozone Generator optional E SpaGlo LED Light System optional E CONTROLS...

Page 26: ...come lodged inside the valve body It is very important that this debris is removed as soon as possible to avoid damage to the valve To accomplish this follow this procedure 1 Turn off power to the spa...

Page 27: ...a wet dry vacuum or a sponge 3 It will be necessary to remove all water from the interior plumbing 4 Remove the filter lid floating weir basket and filter cartridge Clean the filter cartridge and sto...

Page 28: ...asives or solvents since they may damage the shell surface NEVER USE HARSH CHEMICALS Damage to the shell by the use of harsh chemicals is not covered under the warranty IMPORTANT Some surface cleaners...

Page 29: ...d the labels carefully and follow directions precisely Though chemicals protect you and your spa when used correctly they can be hazardous in concentrated form Always observe the following guidelines...

Page 30: ...sure of the total amount of dissolved calcium in the water Calcium helps control the corrosive nature of the spa s water That s why calcium low water commonly known as soft water is not recommended It...

Page 31: ...njunction with all of the other products in this system It is important to follow the recommended application and maintenance programs outlined for each product s use If the spa is being used over an...

Page 32: ...be no residual of silver ions present in the water eliminating them from the sanitizing process Questions How often should the Monarch Silver cartridge be replaced Answers The cartridge must be repla...

Page 33: ...ime is simply the amount of time a user spends in the spa Sanitizer Needed is the amount of Free Available Chlorine FAC needed to accommodate the number of users and their combined usage time For exam...

Page 34: ...nce program based on recognized and documented industry standards still be followed when using an ozone purification system to assure water sanitation and the highest quality purified water Cleaning t...

Page 35: ...e extremely high High sanitizer levels can chemically burn or discolor the spa s shell or the underside of the cover Then after a period of time the sanitizer level dispensed by the floater will fall...

Page 36: ...Available Chlorine Halogen Any one of these five elements fluorine chlorine bromine iodine and astatine MPS Monopersulfate is a non chlorine oxidizer Oxidizer The use of an oxidizing chemical is to pr...

Page 37: ...just pH and or alkalinity to recommended range Run jet pump s and clean filter Drain and refill the spa Shock spa with sanitizer Add sanitizer Adjust pH to recommended range Shock spa with sanitizer A...

Page 38: ...l include any operation of the spa other than in accordance with Watkins Manufacturing Corporation printed instructions or use of the spa in an application for which it is not designed specifically us...

Page 39: ...emperature sensor problem Heater high limit thermostat tripped Temperature set too low Spa cover improperly positioned Dirty Filter Summer Timer On Motor overload condition Control switch failure if j...

Page 40: ...or 50 amp Single phase GFCI protected circuit Moorea Model MOA 36 75 Square feet 4 300 420 Gallons 870 Lbs 5 490 Lbs 115 Lbs per square foot 7 5 x 6 4 Martinique Model MRA 34 75 Square feet 4 300 320...