LED MESSAGES
Water has overheated. DO NOT ENTER THE
WATER. Turn off all power to the spa and contact
your dealer or service organization.
Flow Switch error detection (stuck Flow Switch)
- contact your dealer or service organization.
The high-limit or water temperature sensor has
malfunctioned. Contact your dealer or service
organization.
CALDERA PURE WATER OZONE SYSTEM
The optional Ozone Generator operates during filter
cycles to disburse ozone into the spa through an ozone jet
located in the footwell of the spa. Water flow from the
ozone system should be checked periodically; small bub-
bles should be seen rising from the ozone jet.
SPA TROUBLESHOOTING
Page 12
• Reset circuit breaker.
• Reset GFCI.
• Let cool for 1 hour. Motor overload will reset
automatically. If problem persists, contact your
Caldera dealer.
• Disconnect spa and contact your Caldera dealer.
• Add water to normal level (1 inch above highest
jet).
• Open or clean air valve.
• Add water to normal level (1 inch above highest
jet).
• Clean filter cartridge.
• Remove jet face eyeball and clear orifice.
• Clean suction cover or skimmer basket.
• Set control panel to a higher temperature.
• Align spa cover.
• Clean filter cartridge.
• Circuit breaker or GFCI tripped or OFF.
• Motor overload condition.
• Control switch failure.
• Low water level.
• Air control closed.
• Low water level.
• Dirty filter cartridge.
• Jet blocked.
• Clogged suction or skimmer basket.
• Temperature set too low.
• Spa cover improperly positioned.
• Dirty filter cartridge.
If your spa doesn’t seem to be working the way you believe it should, please review the “START-UP” and
“OPERATION” instructions in this manual. If this doesn’t help you correct the problem, follow the appropri-
ate instructions below. If the problem still is not resolved, call your Caldera dealer.
Nothing works, Blank LED
Display
Noisy pump or Motor
Pump motor will not function
Pump motor runs, but low or
no jet pressure
Spa not heating properly
SYMPTOM
PROBABLE CAUSE
SOLUTIONS
Upon filling or refilling the spa, if the pump is operating and water is not flowing from any of the
jets, the pump may not be properly primed. To correct, perform the following procedures:
• Turn off power to the spa at the breaker and remove the equipment compartment door.
• Loosen the union on the top of the pump to allow the air to escape. When water is present,
hand-tighten the union.
• Turn power back on, activate the pump and check to make sure union is tight enough to keep it
from leaking. Re-install equipment door.