LED MESSAGES

Water has overheated. DO NOT ENTER THE
WATER. Turn off all power to the spa and contact
your dealer or service organization.

Flow Switch error detection (stuck Flow Switch)
- contact your dealer or service organization.

The high-limit or water temperature sensor has
malfunctioned. Contact your dealer or service
organization.

CALDERA PURE WATER OZONE SYSTEM

The optional Ozone Generator operates during filter
cycles to disburse ozone into the spa through an ozone jet
located in the footwell of the spa. Water flow from the
ozone system should be checked periodically; small bub-
bles should be seen rising from the ozone jet.

SPA TROUBLESHOOTING

Page 12

• Reset circuit breaker.

• Reset GFCI.

• Let cool for 1 hour.  Motor overload will reset 

automatically.  If problem persists, contact your 
Caldera dealer.

• Disconnect spa and contact your Caldera dealer.

• Add water to normal level (1 inch above highest 

jet).

• Open or clean air valve.

• Add water to normal level (1 inch above highest 

jet).

• Clean filter cartridge.

• Remove jet face eyeball and clear orifice.

•  Clean suction cover or skimmer basket.

• Set control panel to a higher temperature.

• Align spa cover.

• Clean filter cartridge.

•  Circuit breaker or GFCI tripped or OFF.

•  Motor overload condition.

•  Control switch failure.

•  Low water level.

•  Air control closed.

•  Low water level.

•  Dirty filter cartridge.

•  Jet blocked.

•  Clogged suction or skimmer basket.

•  Temperature set too low.

•  Spa cover improperly positioned.

•  Dirty filter cartridge.

If your spa doesn’t seem to be working the way you believe it should, please review the “START-UP” and
“OPERATION” instructions in this manual. If this doesn’t help you correct the problem, follow the appropri-
ate instructions below. If the problem still is not resolved, call your Caldera dealer.

Nothing works, Blank LED
Display

Noisy pump or Motor

Pump motor will not function

Pump motor runs, but low or
no jet pressure

Spa not heating properly

SYMPTOM

PROBABLE CAUSE

SOLUTIONS

Upon filling or refilling the spa, if the pump is operating and water is not flowing from any of the
jets, the pump may not be properly primed.  To correct, perform the following procedures:

• Turn off power to the spa at the breaker and remove the equipment compartment door.

• Loosen the union on the top of the pump to allow the air to escape.  When water is present, 

hand-tighten the union.

• Turn power back on, activate the pump and check to make sure union is tight enough to keep it

from leaking.  Re-install equipment door.

Priming the pump

OPTION

LED MESSAGES

Summary of Contents for HIGHLAND Series

Page 1: ...QUALITY SPAS AND GAZEBOS SINCE 1976 HIGHLAND SERIES PORTABLE SPA OWNERS MANUAL OLYMPIA CASCADE TETON SIERRA ...

Page 2: ...our spa 10 11 Non operation in a cold climate 11 Winterizing your spa 11 BALANCING THE SPA WATER Balancing your spa water first time 7 3 day a week spa care program 7 SPA TROUBLESHOOTING Basic Troubleshooting 12 LED messages 12 SPA WATER TROUBLESHOOTING 8 START UP INSTRUCTIONS Installing the spa cover 5 Spa features illustration 5 OPERATION Spa side controls 6 Touch pad controls 6 Air controls Hyd...

Page 3: ...ddressed in this manual call your Caldera dealer and he or she will be happy to assist you Pictured below are the Caldera data labels that are locat ed in the spa equipment compartment Locate and read these labels then fill out the blanks below with the corre sponding information If replacement parts are needed it is important that you have the complete data label information for your dealer or se...

Page 4: ...ay lead to unconsciousness with the possibility of drowning E Persons suffering from obesity or with a medical history of heart disease low or high blood pressure cir culatory system problems or diabetes should consult a physician before using a spa F Persons using medication should consult a physician before using a spa since some medications may induce drowsiness while other medications may affe...

Page 5: ...e counties may require permits for the installation of a portable spa Check your local codes for compliance To ensure you can use your spa soon after delivery it is important that you select the voltage prior to setting your spa in place and have a licensed electrician install the wiring if necessary SELECTING THE VOLTAGE FOR YOUR SPA Your spa is designed to operate at either 120 or 220 volts 60 H...

Page 6: ...mperature is displayed This will increase or decrease the set temperature depending on which direction was last chosen Each successive press will change the set temperature by one degree in the same direction If you want to adjust the temperature in the opposite direction wait four seconds to allow the display to revert to the actual water temperature Press the touch pad to display the set tem per...

Page 7: ...trol panel 3 Filter compartment 4 Temperature sensor 5 Spa light TETON MODEL SHOWN FEATURES AND LOCATIONS MAY VARY IN OTHER MODELS 3 7 1 2 4 5 6 8 9 SPA FEATURES 6 Drain suction fitting 7 Inlet for optional ozone 8 Magna Jets 9 Euro Jets ...

Page 8: ...e start of the first cycle Each filter cycle is two hours in duration During filtration the pump s low speed runs continu ously If you want to change the filter cycles start times turn the power to the spa off and back on at the time of day you want the first cycle to begin ECONOMY STANDARD OPERATING MODE When you turn on electrical power to your spa it will automatical ly run in the STANDARD oper...

Page 9: ...y by adding Spa Up 1 oz at a time retesting until the Alkalinity The instructions below will assist you with balancing the spa water for the first time You will need the following items 3 Way Test Strips or Test Kit Spa Up and Spa Down for pH control Spa Defender for calcium and scale control Metal Gone for breakdown of mineral deposits Renew for shock treatment Bromine or Chlorine for sanitizing ...

Page 10: ...ill Excessive organics Shock with RENEW Organic Buildup Scum Body oils and dirt Wipe off scum with a clean rag Depending on Ring Around The Tub severity drain spa use a spa surface and tile cleaner to remove the scum refill spa and adjust water Inadequate filtration Clean filter with a filter cleaner or degreaser Algae High pH Shock with RENEW adjust pH Low free chlorine bromine Shock with RENEW m...

Page 11: ...trict water flow If the filter is not cleaned on a regular basis the filter may clog and restrict water flow which causes improp er filtration and poor jet performance See FILTER CARTRIDGE REMOVAL AND CLEANING INSTRUCTIONS on page 10 Two months heavy usage Drain your spa Follow the procedures outlined in DRAINING Five months light usage YOUR SPA on page 10 Clean the spa with Spa Multi Purpose Clea...

Page 12: ...LB REPLACEMENT To replace the spa light bulb turn all power to the equip ment module OFF Locate the rear of the spa light and remove the bulb socket by turning it counterclockwise 1 4 turn Pull the bulb from the socket and replace by revers ing the above steps CAUTION The replacement bulb must be the same rat ing as the factory installed bulb or standard automotive type 912 SPA COVER CARE CLEANING...

Page 13: ... pump will stop operating and freeze protection will be lost possibly resulting in freeze damage to the spa spa plumbing and or components Such damage is not covered by warranty WINTERIZING YOUR SPA If the spa is located where freezing temperatures occur and you do not intend to use your spa for an extended peri od follow steps 1 through 7 outlined in DRAINING YOUR SPA on page 10 then complete the...

Page 14: ...er Clean filter cartridge Circuit breaker or GFCI tripped or OFF Motor overload condition Control switch failure Low water level Air control closed Low water level Dirty filter cartridge Jet blocked Clogged suction or skimmer basket Temperature set too low Spa cover improperly positioned Dirty filter cartridge If your spa doesn t seem to be working the way you believe it should please review the S...

Page 15: ...Page 13 NOTES ...

Page 16: ...Caldera Spas Quality Spas and Gazebos Since 1976 Copyright Caldera Spas 2000 PART 38667 REV A 2 00 ...