WARNING!

THE EXACT PHYSICAL LOCATION  OF THE TERMINALS ON THE GFCI BREAKER

WILL VARY BETWEEN MANUFACTURERS.  CONNECTING THE HOT WIRE TO THE

NEUTRAL TERMINAL WILL CAUSE IRREVERSIBLE DAMAGE TO THE CONTROL BOX.

** Refer to NEC 250-122 (table)

*PROVIDED WITH SPA.

NOTE: ALL WIRING SHOULD BE COPPER.

230 Volt Permanently Connected

** Refer to NEC 250-122 (table)

NOTE: The wire connections to GFCI breakers are for reference only. Always ensure the white neutral wire is connected to the load neutral of the 30 amp breaker.

 

Strip wire 

insulation back 

½” 

Entire stripped 

end of wire 

must be inside 

Terminal 

Block 

After step 6, 

pull on wire to 

ensure proper 

installation  

Remove 

screwdriver 

Install 

Stripped end 

of wire into 

Terminal 

Block

 

Push top of 

screwdriver away 

from wire 

Terminal

 

Block

 

Insert 

screwdriver to 

engage cage 

clamp

 

4

6

1/2”

3

5

3

WIRE INSTALLATION

FOR CONTROL BOX TERMINAL BLOCK

 

(Layout of Spa’s Terminal Blocks may vary)

Wire Installation Steps

Refer to spa’s wiring  

diagram on back of Control 

Box Cover for proper wiring 

and jumper configuration!

(1 cm)

(1 cm)

Summary of Contents for paradise series

Page 1: ...__________________________ DEALER ____________________________________________________________________________ ADDRESS ___________________________________________________________________________ TELEP...

Page 2: ...a good grip when wet Proper drainage is essential to prevent a build up of water around the spa When building a new room for the spa it is recommended that a floor drain be installed The humidity wil...

Page 3: ...the manufacturer If you are interested in having a concrete slab brick surface or wood deck installed your Calderadealer should be able to suggest a qualified licensed contractor DELIVERY ACCESS First...

Page 4: ...completion of the delivery SPA DIMENSIONS Model Width W Length L Height H MAKENA 36 91 cm 7 5 226 cm 7 5 226 cm SALINA 36 91 cm 7 5 226 cm 7 5 226 cm MARTINIQUE 34 88 cm 7 5 226 cm 6 4 193 cm SEYCHEL...

Page 5: ...AKENA and SALINA NOTE All dimensions are approximate measure your spa before making critical design or pathway decisions Configuration and location may change without notice SPA DRAIN FRONT VIEW ELECT...

Page 6: ...33cm PEDESTAL 3in OVERALL 76 70in 194 83cm SPA DRAIN OUTLET ELECTRICAL ELECTRICAL OUTLET FRONT VIEW 6 35cm 2 50in 10 42in 77 47cm 26 48cm 30 50in 34 00in 86 36cm DOOR 56 75in 144 15cm OUTLET BOTTOM V...

Page 7: ...forced concrete pad or structurally sound deck able to support the dead weight found in the chart on the back page WARNING The SEYCHELLES must not be shimmed in any manner DOOR 65 165 cm FRONT VIEW EL...

Page 8: ...thick reinforced concrete pad or structurally sound deck able to support the dead weight found in the chart on the back page WARNING The REUNION must not be shimmed in any manner DOOR 65 165 cm FRONT...

Page 9: ...8in 198 76cm PEDESTAL 210 03cm OVERALL OVERALL 13 81cm 83in R5in PEDESTAL 150 50cm 59in 64in 7 35cm 3in 3in 7 35cm ELECTRICAL OUTLET 11in 6 35cm 2 5in 29 02cm 29 5in 74 92cm 23 5in 59 80cm ELECTRICAL...

Page 10: ...ut it should not be closer than 5 feet 1 5 m from the spa water edge NEC 680 38 to 41 A 3 INSTALLATION NOTE After the spa has been installed your electrician can connect the conduit from the subpanel...

Page 11: ...ays ensure the white neutral wire is connected to the load neutral of the 30 amp breaker Strip wire insulation back Entire stripped end of wire must be inside Terminal Block After step 6 pull on wire...

Page 12: ...ry panel functions Optional CALDERA Entertainment System Explain the safety features ______________ GFCI Heater high limit General spa operation maintenance orientation ______________ Water quality an...

Page 13: ...______ Telephone _______________________________________________________________________________ Name _______________________________________________________________________________ Telephone ________...

Page 14: ......

Page 15: ......

Page 16: ...13 m 36 91 cm 75 ft 7 m 4 000 330 gallons 1 250 liters 945 lbs 430 kg 4 745 lbs 2 160kg 120 lbs ft 580 kg m 230 volt 30 or 50 amp Single phase GFCI protected circuit REUNION 7 0 x 7 0 2 13 m x 2 13 m...

Reviews: