background image

CONTROLS AND EQUIPMENT

7

1. Air Control
2. Euro-Pulse Jet
3. Euro Jet
4. Air Jet
5. MagnaSsage Jet

6. Magna Jet
7. VersaSsage Jet
8. Whirlpool Jet
9. Euphoria Jet
10. Diverter Valve

11. Drain
12. Light
13. Ozone Jet
14. Control Panel
15. Pillow

16. Filter Compartment
17. Auxiliary Panel
18. Grab Rail

1

1

1

2

3

3

3

3

4

4

4

4

4

5

6

7

7

8

9

10

10

10

11

11

11

12

14

18

15

15

15

17

16

1

3

3

4

4

4

2

3

4

OVERHEAD VIEW

TAHITIAN UTOPIA

13

1

Summary of Contents for UTOPIA GENEVA

Page 1: ...Utopia Series Portable Spa Owner s Manual Geneva Niagara Tahitian Hawaiian Utopia Series Portable Spa...

Page 2: ...nstructions 22 Fiber Optics Light 22 Diverter Valve Maintenance 22 Winterizing Your Spa 23 Draining Your Spa 24 Care of the Spa Pillows 25 Care of the Exterior 25 Care of the Spa Cover 25 WATER QUALIT...

Page 3: ..._______________________ SPA MODEL SERIAL NUMBER ______________________________ COVER SERIAL NUMBER ____________________________________ In most cities and counties permits will be required for the ins...

Page 4: ...eded to comply with local requirements WARNING To reduce the risk of electrical shock replace a damaged cord immediately Failure to do so may result in death or serious personal injury due to electroc...

Page 5: ...that wet surfaces can be very slippery Take care when entering or exiting the spa Increased side effects of medication The use of drugs alcohol or medication before or during spa use may lead to uncon...

Page 6: ...ur Caldera Spa Dealer and request Part 003021 IMPORTANT SPA INSTRUCTIONS The following contains important spa information and we strongly encourage you to read and apply them DO Use and lock the cover...

Page 7: ...ersaSsage Jet 8 Versa Jet 9 Euphoria Jet 10 Diverter Valve 11 Drain 12 Light 13 Ozone Jet 14 Control Panel 15 Pillow 16 Filter Compartment 17 Auxiliary Panel 18 Grab Rail 1 1 1 1 2 3 4 4 4 4 4 6 5 7 7...

Page 8: ...9 CONTROLS AND EQUIPMENT 6 1 Air Control 2 Euro Pulse Jet 3 Euro Jet 4 Air Jet 5 Magna Jet 6 VersaSsage Jet 7 Whirlpool Jet 8 Euphoria Jet 9 Diverter Valve 10 Drain 11 Light 12 Ozone Jet 13 Control P...

Page 9: ...VersaSsage Jet 8 Whirlpool Jet 9 Euphoria Jet 10 Diverter Valve 11 Drain 12 Light 13 Ozone Jet 14 Control Panel 15 Pillow 16 Filter Compartment 17 Auxiliary Panel 18 Grab Rail 1 1 1 2 3 3 3 3 4 4 4 4...

Page 10: ...gna Jet 7 Whirlpool Jet 8 Euphoria Jet 9 Diverter Valve 10 Drain 11 Light 12 Ozone Jet 13 Control Panel 14 Pillow 15 Filter Compartment 16 Auxiliary Panel 17 Grab Rail 1 2 3 3 3 3 4 4 4 4 11 11 14 16...

Page 11: ...esult INDOOR BASEMENT INSTALLATION Be aware of some special requirements if you place your spa indoors Water will accumulate around the spa so flooring materials must provide a good grip when wet Prop...

Page 12: ...Control Module warranty POWER CONNECTION To connect power to the spa refer to 230 VOLT WIRING SCHEMATIC DIAGRAM and POWER CONNECTION ACCESS illustrations above then proceed with the following steps 1...

Page 13: ...IMPORTANT Be sure that the air control valves are open by turning each one counterclockwise and checking to see that all the diverters are in position 1 or position 3 see illustration on air control a...

Page 14: ...cks and to compensate for vinyl shrinkage in cold weather Attach the locks with the screws provided and insert the cover tie down straps into the locks Keeping the cover in place any time the spa is n...

Page 15: ...he tabs on either side of the nozzle Additional MagnaSsage rotating nozzles and dual port nozzles are available from your Caldera dealer Both the Magna and MagnaSsage jets allow you to regulate the fo...

Page 16: ...lse jets 4 VersaSsage jets Front Jet Pump Jet System 3 2 Euro Pulse jets 4 VersaSsage jets Activates right side diverter Right Side Jet System 1 1 Whirlpool jet on right wall Front Jet Pump Jet System...

Page 17: ...2 Euro Pulse jets 4 VersaSsage jets Back Jet Pump diverter position 2 activates both Back Jet Pump Systems 1 and 3 Front Jet Pump diverter position 2 activates both Front Jet Pump Systems 1 and 3 Righ...

Page 18: ...jets 4 VersaSsage jets 16 Back Jet Pump diverter position 2 activates both Back Jet Pump Systems 1 and 3 Front Jet Pump diverter position 2 activates both Front Jet Pump Systems 1 and 3 Right Side div...

Page 19: ...2 Euro Pulse jets 4 VersaSsage jets Back Jet Pump diverter position 2 activates both Back Jet Pump Systems 1 and 3 Front Jet Pump diverter position 2 activates both Front Jet Pump Systems 1 and 3 Righ...

Page 20: ...ouch pads that allow you to set the water temperature as well as the hydrotherapy jets mood light and optional jets from the spa control panel Display Inversion You may invert the main four digit disp...

Page 21: ...This system is initiated 60 seconds after the spa is powered up then operates one time per day Summer Logic The circulation pump heater and ozone are disabled if the temperature regulating system det...

Page 22: ...EQUIPMENT COMPARTMENT JET PUMP SIDE 20 4 4 1 2 3 3 3 5 6 1 Jet Pump 2 Ozone Injector 3 Unions 4 Air Pump 5 Light 6 Thermostat 1...

Page 23: ...A B C D EQUIPMENT COMPARTMENT CONTROLS SIDE 21 A Control Box B Pressure Switch C Circulating Pump D Low Flow Heater E Caldera Ozone System E...

Page 24: ...ecuring the light assembly access cover and remove the cover 2 The light assembly is positioned in the light assembly holder To remove pull the light assembly straight up 3 Remove the light assembly f...

Page 25: ...seal 5 With the vacuum blowing into the opening of the filter compartment note that air escapes through one of the suction openings in the footwell Close this suction opening by installing a 1 1 2 NPT...

Page 26: ...rain cap 5 Attach drain hose to a garden hose and direct to an appropriate draining area keeping the hose below the water line 6 After your spa is empty clean the shell and filter cartridge See IMPORT...

Page 27: ...in irritants Keep all cleaners out of the reach of children and use care when applying SPA SKIRT When cleaning the skirt of your spa use only a soft cloth or sponge with a mild soap and water solution...

Page 28: ...Kit or Test Strips to ensure the accuracy of the test results BASIC CHEMICAL SAFETY When using chemicals read the labels carefully and follow directions precisely Though chemicals protect you and you...

Page 29: ...d to the next step BALANCING THE CALCIUM HARDNESS CH A The recommended Calcium Hardness CH level for your spa is 150 200 ppm B Calcium Hardness is a measure of the total amount of dissolved calcium in...

Page 30: ...se the FAC by adding granulated Sodium Dichlor E If the FAC is too high the water can cause discomfort to the user s eyes lungs and skin Simply allow some time to pass The FAC level will drop naturall...

Page 31: ...iminished SUPPLEMENTAL WATER MAINTENANCE Proper water sanitation and mineral balance pH control are absolutely essential for a complete spa water maintenance program Here are three other popular water...

Page 32: ...ighest quality purified water Cleaning the Ozone Injector On occasion a mineral build up may clog the ozone injector causing a lack of flow or low flow of ozone bubbles To prevent this refer to the fo...

Page 33: ...anitizer will chemically burn blister the spa shell Although your spa shell is specifically designed to resist the effects of spa chemicals no spa surface can withstand this type of highly concentrate...

Page 34: ...ned at recommended residuals to protect bathers against pathogenic organisms which can cause disease and infection in spa water Scale Rough calcium bearing deposits that can coat spa surfaces heaters...

Page 35: ...Add sanitizer Adjust pH and or alkalinity to recommended range Run jet pump s and clean filters Drain and refill the spa Shock spa with sanitizer Add sanitizer Adjust pH to recommended range Shock sp...

Page 36: ...hall include any operation of the spa other than in accordance with Watkins Manufacturing Corporation printed instructions or use of the spa in an application for which it is not designed specifically...

Page 37: ...sn t seem to be working the way you believe it should please review the start up and operation instructions in this manual If this doesn t help you correct the problem follow the appropriate instructi...

Page 38: ...ldera dealer Pressure Switch flashing The pressure switch is not detecting an adequate amount of water flow Make sure the spa is filled to 1 inch above the highest jet The spa will continue to operate...

Page 39: ...Geneva 38 100 Square feet 4 300 475 Gallons 920 Lbs 5 915 Lbs 115 Lbs per square foot 230 volt 50 amp Single phase GFCI protected circuit Tahitian 36 100 Square feet 4 300 360 Gallons 790 Lbs 4 825 L...

Reviews: