background image

22

METhOdS FOR TESTINg ThE SPA wATER 

Accurate water testing and analysis is an important part of effectively managing your spa water. You must have the ability to test for:

•  Total Alkalinity (TA)
•  Calcium Hardness (CH)
•  pH
•  Sanitizer

Two types of testing methods are recognized and recommended by Watkins Manufacturing Corporation:
1.   

The reagent Test Kit

 is a method which provides a high level of accuracy. The reagents come in either liquid or tablet form.

2.   

Test Strips

 are a convenient testing method used by many spa owners. Keep in mind that test strips are susceptible to heat and moisture contamination, which will 

result in inaccurate readings. 

 Always read and carefully follow the directions included with the Test Kit or Test Strips to ensure the accuracy of the test results.

bASIC ChEMICAl SAFETY

When using chemicals, read the labels carefully and follow directions precisely. Though chemicals protect you and your spa when used correctly, they can be hazardous 

in concentrated form. Always observe the following guidelines:

•  Allow only a responsible person to handle spa chemicals. 

KeeP THeM OUT OF THe reaCH OF CHIldreN.

•  Accurately measure the exact quantities specified, never more. Do not overdose your spa.
•  Handle all containers with care. Store in a cool, dry, well ventilated place.
•  Always replace the caps on their proper containers when not in use. 
•  Don’t inhale fumes or allow chemicals to come in contact with your eyes, nose, or mouth. Wash your hands immediately after use.
•  Follow the emergency advice on the product label in case of accidental contact, or if the chemical is swallowed. Call a doctor or the local Poison Control Center. 

If a doctor is needed, take the product container along with you so that the substance can be identified.

•  Don’t let chemicals get on surrounding surfaces or landscaping. 
•  Don’t use a vacuum cleaner to clean up chemical spills.
•  Never smoke around chemicals. Some fumes can be highly flammable.
•  Don’t store any chemicals in the spa equipment compartment.

hOw TO Add ChEMICAlS TO ThE SPA wATER

IMPOrTaNT:

 All spa water chemicals (other than 

FrOG

 cartridges), including MPS Plus (shock), chlorine, granulated pH increaser or decreaser, granulated total 

alkalinity increaser, calcium hardness increaser, liquid stain and scale inhibitor, and liquid de-foamer must always be added directly into or in front of the filter 

compartment while a jet pump is running, and it must run for a minimum of ten minutes. 

To Administer Spa water Chemicals:

1.  Fold back the cover and remove the filter compartment cover. 
2.  Carefully measure the recommended amount of chemical and slowly pour it over the filter basket area. Use care not to splash chemicals on your hands, in your 

eyes, on the spa sheet surface, or on the siding. 

3.  Replace the filter compartment cover. After ten minutes, shut off the jet pump(s) and close the cover. 

risk of drowning:

 Never leave an open spa unattended! 

WarNING: 

High sanitizer levels can cause discomfort to the user’s eyes, lungs and skin. Always allow the sanitizer level to fall to the recommended range before 

using the spa.

 IMPOrTaNT "SUPer CHlOrINaTION/NON-CHlOrINe SHOCK TreaTMeNT" NOTe:

 After administering a super chlorination treatment or non-chlorine shock to 

your spa, leave the cover open for a minimum of 20 minutes to allow the oxidizer gas to vent. A high concentration of trapped oxidizer gas which may exist as a result of 

the shock treatment (not daily sanitation) may eventually cause discoloration or vinyl degradation to the bottom of the cover. This type of damage is considered chemical 

abuse and is not covered under the terms of the limited warranty.

WaTer QUalITY aNd MaINTeNaNCe

Summary of Contents for vacanza series

Page 1: ...VACANZA SERIES 2 0 1 4 O W N E R S M A N U A L...

Page 2: ...SPA MODEL SERIAL NUMBER ____________________________ COVER SERIAL NUMBER ________________________________ In most cities and counties permits will be required for the installation of electrical circu...

Page 3: ...ONS Control Operation 14 System Mode 15 Manual Clean Cycle 15 Tools Menu 15 Audio Menu Optional 17 Air Control 19 Hydrotherapy Jets 19 Waterfall Valve 19 WATER QUALITY AND MAINTENANCE Water Terminolog...

Page 4: ...tion of this important safety device test according to the following instructions per electrical configuration Cord Connected 115 volt 20 amp models The GFCI is located at the end of the power cord Be...

Page 5: ...ion fitting There is a danger of slipping and falling Remember that wet surfaces can be very slippery Take care when entering or exiting the spa Never operate spa if the suction fittings are broken or...

Page 6: ...the control box by the spa owner will void the warranty If you have an operational problem carefully go through the steps outlined in the Troubleshooting section If you are not able to resolve the pro...

Page 7: ...manual and printed instructions on all water care chemical products packaging Test the water regularly to ensure proper levels of sanitizers pH and other water care requirements Drain clean and refil...

Page 8: ...he spa s safety features Improper wiring may also cause electrocution risk of fire and other risks of injuries Please read and follow the electrical installation requirements and instructions for your...

Page 9: ...to the wiring diagram below 1 Connect the 8 AWG WHITE NEUTRAL wire from the Neutral Ground Bar on the main electrical service to the WHITE NEUTRAL Panel Neutral Pigtail of the subpanel 2 Connect the...

Page 10: ...ALS adjust Total Alkalinity TA to 80 180 ppm Calcium Hardness CH to 50 150 ppm then spa water pH to between 7 2 and 7 8 These procedures are listed in the Water Quality and Maintenance section OPERATI...

Page 11: ...5 volt 20 amp electrical configuration the heating system does not operate simultaneously with the high speed pump On the other hand on the 230 volt system the heating system does operate simultaneous...

Page 12: ...AdaptaFlo jets 7 AdaptaSsage Jets 8 Outlet for optional ozone 9 Drain suction fitting 10 Pillow 11 Waterfall valve 12 Acquarella Waterfall 13 FROG Palatino Marino 1 1 2 4 7 9 5 1 1 6 10 8 8 9 3 11 12...

Page 13: ...IT IN THE FILTER COMPARTMENT AREA THIS IS NOT A SEAT Sitting in this area can cause Restriction of filter pump suction vacuum Damage to components Both can result in bodily harm Should damage occur to...

Page 14: ...r optional ozone 10 Drain suction fitting 11 Pillow 12 Grab Rail 13 FROG aventine 1 2 3 4 6 7 8 7 12 5 11 6 8 10 9 8 13 WARNING DO NOT SIT IN THE FILTER COMPARTMENT AREA THIS IS NOT A SEAT Sitting in...

Page 15: ...aSsage Jets in back right 2 AdaptaFlo Jets and 1 Euro Jet in right center 4 Euro Jets in footwell PALATINO MARINO System 1 8 Euro Jets in back left 2 AdaptaFlo Jets in back center Acquarella Waterfall...

Page 16: ...taFlo Jet and 1 AdaptaSsage in front left tarino System 1 Menu A Diverter in position 8 Euro Jets in back left 2 AdaptaSsage Jets in back right Lounge Acquarella Waterfall 2 Euro Jets in footwell 3 Eu...

Page 17: ...T MENUS 14 AVENTINE System 1 2 Euro Jets in back left 3 AdaptaFlo Jets in back left 2 Euro Pulse Jets in arm rests 4 Euro Jets in back right 2 AdaptaFlo Jets in back right 1 AdaptaFlo Jet in front rig...

Page 18: ...ystem 1 jet pump runs on high speed 3rd press System 1 System 2 jet pumps run on high speed 4th press System 2 jet pump runs on high speed 5th press Both Systems jet pumps are off Tarino Aventine Spa...

Page 19: ...ng features SPA Lock and Temperature Lock are enabled from the control panel by pressing the SET button until the Tools menu is illuminated Then press the TEMP button to enter the TOOLS submenus Use t...

Page 20: ...leep mode to work in the evening hours the spa must be powered up in the early morning hours The Sleep Mode will always be active the 6 12 hours between the end of F2 and the begining of F1 depending...

Page 21: ...stem ON Press the TEMP button to display PWR and turn the audio system OFF Audio power must be ON to advance to the other audio screens IMPORTANT The power can take up to a few seconds to turn on or o...

Page 22: ...button to raise the Bass or press TEMP button to lower the Bass TO ADJUST BAlance From the SETUP menu 1 Press the TEMP button to display one of four audio sources IPOD TV AUX BLUE 2 Press the SET but...

Page 23: ...jets provide a rotating massage pattern Euro Jets The Euro Directional jets with eyeball nozzles deliver a direct more focused massage The Euro Pulse jet features a special insert that creates a soft...

Page 24: ...ramines and will not alter the water s pH Pathogen A microorganism such as bacterium that cause disease pH The measure of the spa water s acidity and alkalinity The recommended pH for the spa water is...

Page 25: ...substance can be identified Don t let chemicals get on surrounding surfaces or landscaping Don t use a vacuum cleaner to clean up chemical spills Never smoke around chemicals Some fumes can be highly...

Page 26: ...lution a mixture of 75 hard and 25 soft water will usually yield a reading within the correct range If soft water is not available or practical for you a stain and scale inhibitor should be added to t...

Page 27: ...Plus or sodium dichlor chlorine Sodium dichlor may be a more appropriate weekly shock for those users that experience heavy bather load conditions The following optional products can be used in conjun...

Page 28: ...er to establish the correct setting on cartridges for User Load and Usage Time versus Sanitizer Needed User Load is the spa is the number of times anyone enters the spa Usage Time is simply the amount...

Page 29: ...n incorrect product such as tri chloro which has a very low pH 2 6 dissolves too quickly in hot water resulting in extremely high levels of chlorine and is designed for concrete or plaster swimming po...

Page 30: ...em to assure water sanitation and the highest quality of purified water Cleaning the Ozone Injector On occasion a mineral build up may clog the ozone injector causing a lack of flow or low flow of ozo...

Page 31: ...e chemically induced spa surface blistering chemical abuse very quickly WATER QUALITY AND MAINTENANCE Spa water maintenance troubleshooting guide Cloudy Water Water Odor Chlorine Odor Musty Odor Dirty...

Page 32: ...ldera Spa Water Maintenance program are needed to protect the user from water borne pathogens disease causing microbes and to prevent corrosion of spa components Question Why isn t water chemistry dam...

Page 33: ...illow retainers to slip into the recess in the back of the pillow 4 Keeping the pillow slightly bent slide the other pillow retainer into the recess in the back of the pillow 5 After all the pillow re...

Page 34: ...the outlet of the hose to an appropriate draining area Spa water with a high sanitizer level may harm plants and grass 3 Open the valve by turning the knob The spa will drain by gravitational flow IMP...

Page 35: ...re install your filter and follow the Start up and Refill Procedures in the Operating Instructions section of the Owner s Manual IMPORTANT Always keep spa covered when not in use whether it is empty...

Page 36: ...conds to reset the heater high limit If tripping continues clean the filter then if tripping still occurs call for service Water temperature significantly different from display temperature Display sh...

Page 37: ...pump s to allow the air to escape When water is present hand tighten the union Turn power back on activate the pump and check to make sure union is tight enough to keep it from leaking Re install equi...

Page 38: ...r purchaser of the Caldera spa when purchased and originally installed within the boundaries of the United States This warranty begins on your delivery date of the spa but in no event later than one y...

Page 39: ......

Page 40: ...lbs 120 lbs per Square foot 230 volt 50 amp Single phase GFCI circuit Marino Model MRN 7 0 x 7 0 36 65 square feet 4 000 360 gallons 836 lbs 4 888 lbs 120 lbs per Square foot 230 volt 50 amp Single p...

Reviews: